3.10.4 Operation Checks
3.10.4.1 Converter Check
A very easy way to ensure a pair of
FTH4-1000M or FTH4-100M
is passing traffic, is to place them between two PCs. Connect PC1 to
LAN of one converter and PC2 to LAN of the other converter. When the two PCs can ping each other, it indicates
FTH4-1000M or FTH4-100M
pair is operational.
3.10.4.2 Ping Test
With the device reset to factory default, connect a PC and configure the PC to the 10.1.1.0 network (10.1.1.100 recommended). Use a PC
to ping the device at its factory default IP address of 10.1.1.1. With a direct connection to PC, there should be no time outs and ping latency
should be less than 1 millisecond. If you switch to another device, be sure to clear the PC ARP table. Every device has the same default IP
address, but every unit has a different MAC address. To clear the
PC’s MAC table, open a command window and execute the command ‘arp –
d’. In addition, if you disconnect the PC from any LAN connection and then re-connect, the ARP table should also be cleared.