FSW3208M 

8+2 Gigabit Ethernet 
WebSmart Switch 

 

Содержание FSW3208M

Страница 1: ...FSW3208M 8 2 Gigabit Ethernet WebSmart Switch ...

Страница 2: ......

Страница 3: ...ed or unauthorized application the Buyer shall indemnify and hold CTC Union Technologies and its officers employees subsidiaries affiliates and distributors harmless against all claims costs damages expenses and reasonable attorney fees arising out of either directly or indirectly any claim of personal injury or death that may be associated with such unintended or unauthorized use even if such cla...

Страница 4: ...t Smart Switch Stand alone Rack Type User Manual Version 3 4 April 2008 Release This manual supports the following model FSW3208M This document is the official release manual Please check CTC Union s website for any updated manual or contact us by E mail at info ctcu com Please address any comments for improving this manual or to point out omissions or errors to marketing ctcu com Thank you ...

Страница 5: ... TAG BASED VLAN 13 2 1 4 TAG BASED VLAN 14 2 1 5 PORT TRUNKING 17 2 1 6 PORT MIRRORING 18 2 1 7 QUALITY OF SERVICE 19 2 1 8 STORM CONTROL 21 2 1 9 LACP 21 2 1 9 LACP 22 2 1 10 RSTP 23 2 1 11 IGMP 25 2 1 12 802 1X 26 2 2 MONITORING 26 2 2 MONITORING 27 2 2 1 PORT STATISTICS 27 2 2 2 LACPSTATUS 28 2 2 3 RSTPSTATUS 29 2 2 4 IGMPSTATUS 29 2 2 5 PING 29 2 2 5 PING 30 2 3 MAINTENANCE 31 2 3 1 WARM REBOO...

Страница 6: ......

Страница 7: ... the matching effort between straight and cross over line issues 8G web smart switch supports both port based and 802 1Q tag based VLAN to catch up the application needed for coming VLAN age To increase bandwidth application it supports up to 4 trunk groups with maximum 8 ports on one Trunk moreover these trunk ports are with fair over function to provide redundant back up when one or some of trun...

Страница 8: ...92 168 223 254 Default Password admin 1 2 2 Terminal mode default setting are baud rate 115 200 attribute 8 None 1 None Terminal mode operation Default Password admin Once terminal is connected the basic operation rule are shown below Press to find root operation page then choose command by typing little alphabets After enter command page Press to find command parameters and format further more ty...

Страница 9: ...ow up The left part on the page provides the function menus while the right part provides the individual configuration value or system parameters value Function manuals are divided into three categories they are Configuration Monitoring and Maintenance all functions are shown briefly below ...

Страница 10: ...ersion MAC address IP address subnet mask IP gateway default VLAN value of management port name password timeout value and SNMP communities etc Once user finish the setting he must press the Apply button to execute all his setting and whenever he needs he may press the Refresh button to get updated status of system information ...

Страница 11: ... group VID 1 so they can communicate to each other and hence any port can be used as web management port to talk with CPU port inside but for example assume user uses port 1 as web management port then user create VLAN ID 10 on port 7 8 and create another VLAN ID 20 on port 5 6 now 3 VLAN groups will be shown on VALN group table after he press Apply button If VLAN 10 and VLAN ID 20 must be isolate...

Страница 12: ...ol and jumbo frame however be noticed that the jumbo frame is global setting it can t be set on individual port but on all ports at a time A default diagram is shown below Choose and click the ports you want to set for example choose port 1 and set port 1 Flow Control enable then press Apply after execution diagram will shown below ...

Страница 13: ...er new port based VLAN better set another group ID rather than 1 After press Apply button the screen will show a updated VLAN Group table no matter user add a new group or delete a VALN group The important thing is that port based VLAN is valid only within same device it will never be valid cross the devices A default diagram is shown below Choose and click the ports you want to group for example ...

Страница 14: ... same device but also cross the devices as long as they are with same VLAN ID the other important thing is user must keep in mind that the VLAN ID of CPU port must be one of the VLAN group if user wants to manage through one of the ports of that VLAN group otherwise if there is no port with same VLAN ID as CPU port the web management in band control will be failed because different VLAN different ...

Страница 15: ...t Tag VLAN Management Group to 10 by pressing Apply command then move RJ 45 web management port from port 1 to port 8 then user can perform web management from new RJ 45 port again But if user forget what group that CPU belongs to there are two ways to solve this condition below 1 Through console port check Configuration of IP if he gets password or 2 Press Reset button few seconds let system retu...

Страница 16: ... VID is not the same 3 Accept Packet Type ALL Accept all ingress frames Tagged only Only accept ingress frames with VLAN tag 4 Port VID Set Port VID value 1 4096 then an untagged ingress frames will bear this value a its VID usually this port is connected to un tag device legacy device then this frame become a tagged frame hence it can be handled inside the switch as a member of same VID group Set...

Страница 17: ...ng A default diagram is shown below and up to 4 groups are provided Choose and click the trunk ports you want to group for example choose port 1 port 2 into group 1 then press Apply after execution diagram will shown below ...

Страница 18: ...rroring A default diagram is shown below Choose and click the ports you want to monitor for example choose port 2 is mirror port And the mirror source is port 5 then press Apply after execution diagram will shown below ...

Страница 19: ...must wait until all other higher priority frames are sent serviced then it gets service WRR Mode means different priority are with different weighting to get service that is within a time period the service times chance are a ratio among these 4 classes user may choose one of preset setting from the manual A default diagram with Strict Queue Mode is shown below Choose the port based priority level...

Страница 20: ... this means frames are with VLAN Tag inside the switch the priority in the Tagged frame 2 bytes Tag in total must be set by application program But 8 priority levels map into 4 class also must be done same as explained in previous paragraph ...

Страница 21: ... click type of storm you want to control for example choose Broadcast storm with 3 964 frames per second as upper limit once the Broadcast frame rate higher than 3 964 frame per second this port will be disabled Press Apply after execution diagram will be shown below ...

Страница 22: ... need to be set per port basis in this webpage Protocol Enabled to enable disable LACP protocol for a port Key Value a number 1 255 to identify the LACP group for a port All member ports in a LACP group have the same key values Key number will be automatically generated if auto value is set Choose and click the trunk ports you want to group For example select port 5 6 7 and port 8 to group into a ...

Страница 23: ...s Enable STP to ensure that only one path at a time is active between any two nodes on the network The Rapid Spanning Tree Protocol RSTP is a more advanced protocol than STP according to IEEE 802 1w standard RSTP can shorten spanning tree convergent time while network topology is changed A default diagram is shown below ...

Страница 24: ...figuration Enter a number 6 through 40 default is 20 Forward Delay the number of seconds a port waits before changing from its Spanning Tree Protocol learning and listening states to the forwarding state Enter a number 4 through 30 default is 15 Force Version normal use RSTP compatible compatible with old STP protocol Port Configuration Aggregations Enable disable the RSTP protocol on aggregation ...

Страница 25: ...nooping for this system IGMP Enabled to globally enable disable IGMP snooping function Router Ports the port that is usually with source of multicast traffic stream Unregistered IPMC Flooding Enabled to set forwarding option for unregistered not joined IP multicast traffic Enabled to flood frames to every port Disable to forward frames only to those IGMP member ports Two options can be set for eac...

Страница 26: ...rized by authentication process Force Authorized client will be authorized anyway Force Unauthorized client won t be authorized anyway Action means execute command on single port or all ports when click Re authenticate authorized again on that port Force Reinitialize force that port initialize Statistic see statistic frames Parameters Define time schedule on Re authentication mode The default diag...

Страница 27: ...27 2 2 Monitoring 2 2 1 Port Statistics Choose and click command manual after execution diagram will shown below user can clear counter or refresh as will ...

Страница 28: ...28 2 2 2 LACP Status Choose and click command manual after execution diagram will shown like below user can refresh at will ...

Страница 29: ...ram will be shown like below user can refresh as will There are IGMP v1 v2 v3 frames will be shown in the network our switch only support IGMP V2 but it will handle some IGMP V3 frames If this switch is Querier it will show Querier state and Query frames it transmitted if it is not Querier it only show how many Querier frames it receives Only one Querier in a network subnet usually Querier is a ro...

Страница 30: ...5 Ping Fill up the IP address you want to ping set Time Out time and Counts for example IP 192 168 223 25441 count 5 time pout 5 sec then press Apply then press Refresh after execution diagram will shown below ...

Страница 31: ...own and then direct the location of the file that is to be updated then press upload if success it will be shown below Software successfully loaded Do you want to activate new software Yes No Press yes then you get new code to execute however after activate the new code then 5 10 seconds later press reset button at front panel so that the new default setting will be also updated because different ...

Страница 32: ...through Ethernet user has to know the IP address subnet mask etc he may get this information by checking the configuration under IP command he also may try to modify the IP address CPU management group used in tag VLAN configuration operation or any other function through terminal mode And most convenient if user is used to configure the tag VALN through terminal mode he won t be interfered by the...

Страница 33: ...33 Key in Command and then key in second level will be shown for example ...

Страница 34: ...34 If user wants to check the IP related information he may do as below All other function can be operate likewise Type up or go back to previous page Contents subject to change without notice ...

Страница 35: ......

Страница 36: ......