background image

FRM220 Chassis Quick Installation Guide

 

29 

 

Line card options 

The 

FRM220

 is capable of supporting a variety of in-band managed or non-in-band managed line 

card types which may be mixed and matched in any slot of the rack. See below for a brief of the line 
cards at the time of this printing. Please refer to the latest version of 

FRM220 NMC User Manual

 for 

details of all the line card options for the 

FRM220

 

Installation 
Introduction 

The Installation  chapter  will  cover  the  physical  installation  of  the 

FRM220-CH08

,  Rack  Mount In-

Band  Managed  Series  Fiber  Converter  Platform  Chassis,  the  electrical  connections,  interface 
connections and cabling requirements. A brief overview of the functional components such as main unit 
and management options will also be outlined in this section. 

 

Required Tools 

You will need these tools to install the 

FRM220-CH08

 

Number 2 Phillips screwdriver for the 3mm and the 12-24 rack installation screws. 

 

Wrist strap or other personal grounding device to prevent ESD occurrences. 

 

Antistatic mat or antistatic foam to set the equipment on. 

 

Site Preparation 

Install the 

FRM220-CH08

 within reach of an easily accessible grounded AC outlet or three wire (-

48VDC, Power return, Earth Ground) central office power. The AC outlet should be capable of furnishing 
100 to 240 VAC. Refer to 2.4 Electrical Installation. Allow at least 10cm (4 inch) clearance at the front 
of the 

CH08

 for the Fiber and other copper cables. 

Mechanical Assembly 

CH08

 is designed for rack mount installation and will require 1U space in a standard EIA 19" or 23" 

rack. 

CH08

 chassis is delivered completely assembled, however power modules and converter cards 

may or may not be installed in the chassis upon delivery. The rack mount adapters may be placed along 
the front or centrally located on the chassis. 

 

Rack mounting 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure. Standard 19" Rack-Mount Installation of 

CH08

 Unit requires 1RU space 

 

 

Brackets are 
installed for 19" 
mounting. 
    (factory installed) 

Содержание FRM220

Страница 1: ...cover FRM220 Chassis QIG sales ctcu com...

Страница 2: ...please visit https www ctcu com en download html 2020 CTC Union Technologies Co LTD All trademarks are the property of their respective owners Technical information in this document is subject to cha...

Страница 3: ......

Страница 4: ...CTION FUNCTION 18 INSTALLATION I 18 RACK MOUNTING OPTION 18 WALL MOUNTING OPTION 18 FRM220 CH02 NMC 19 DESCRIPTION 19 PANELS 20 LED INDICATORS 20 INSTALLATION 20 RACK MOUNTING OPTION I 21 RACK MOUNTIN...

Страница 5: ...SSIS PHYSICAL DIMENSIONS 33 CHASSIS SPECIFICATIONS 34 NMC SNMP 34 LINE CARD OPTIONS 35 INSTALLATION 35 SITE PREPARATION 35 MECHANICAL ASSEMBLY 35 RACK MOUNTING 35 FAN UNITS REMOVAL REPLACEMENT 36 ELEC...

Страница 6: ...s a 12V 1A 12watt switching power adapter wall wart to a 20 slot 2U rack chassis with dual swappable fans and AC or DC power modules This guide will give installation details for each chassis option i...

Страница 7: ...ndalone chassis has the option of adding wall mount capability One wall mount kit is required for installing a single standalone chassis on the wall Each wall mount kit provides a wall mounting bracke...

Страница 8: ...only hand tight Figure CH01 xx Installation Power Connection The graphic below shows the power connections for the CH01 AD with one DC and one AC power supply When two supplies are connected they are...

Страница 9: ...low the screw head to pass through the hole in the bracket The screws in the wall should be screwed in leaving just enough space so the bracket and CH01 xx can be hung securely Figure CH01 xx with Wal...

Страница 10: ...ents on the board Align the card with the slots of the CH01M xx chassis and slide the card all the way in Use the thumb screw to secure the card tightening it only hand tight Figure CH01M xx Installat...

Страница 11: ...ground will connect to the CH01 xx chassis from the IEC connector Each power supply has a respective toggle switch which then sends the input power to the internal supplies The switch is OFF when set...

Страница 12: ...100i Fast Ethernet In band managed converter E1 T1 fiber modem and V35 X21 RS530 fiber modem Features Two slot chassis for FRM220 line cards Support backplane connection between two slots Support DB9...

Страница 13: ...wer 1 is off PWR 2 LED on off Power 2 is on Power 2 is off Console slot select switch Slot 1 console port for slot 1 upper line card configuration Slot 2 console port for slot 2 lower line card config...

Страница 14: ...Module Line Card Installation Installation II The FRM220 CH02M FRM220 CH02M HP a two blade chassis can be installed with one single width blade line card into the chassis The line cards include 10G 2...

Страница 15: ...220 CH02M HP standalone chassis have the option of adding standard EIA 19 rack mount capability The rack mount tray provides mounting for two standalone chassis in a rack Each rack mount tray kit prov...

Страница 16: ...Ethernet E1 Inverse Multiplexer Ethernet over Fiber E1 T1 35 X21 RS530 fiber modem POTS over fiber and RS485 422 232 fiber converter Features Two slot chassis for FRM220 line cards Support backplane c...

Страница 17: ...nt 2500 mA Red Blinking Power voltage is larger than 10 5V but smaller than 9V or power current is larger than 2500 90 mA but smaller than 2500 mA 10 5V Voltage 9V or 2500 90 mA Current 2500 mA Off Tu...

Страница 18: ...H20 rack It can be installed with one single width blade line card into the chassis All types of FRM220 series one module line card can be installed in FRM220 CH02 SMT chassis including 10G 3R Transpo...

Страница 19: ...ltiplexer Ethernet over Fiber E1 T1 35 X21 RS530 fiber modem POTS over fiber and RS485 422 232 fiber converter Features Two slot chassis for FRM220 line cards Support backplane connection between two...

Страница 20: ...D on off Power 2 is on Power 2 is off Installation The FRM220 CH02 NMC a two blade chassis can be installed with one single width blade line card plus an NMC card into the chassis The line cards inclu...

Страница 21: ...02 NMC standalone chassis have the option of adding standard EIA 19 rack mount capability The rack mount tray provides mounting for two standalone chassis in a rack Each rack mount tray kit provides a...

Страница 22: ...card and remote connected stand alone device may be managed through any of the available management interfaces A variety of cards are available that support multi mode or single mode fiber types and c...

Страница 23: ...onductors with a minimum cross section area of 0 75 mm2 DC Power Cord Specification wiring must comply with EN 60950 1 2006 standard Conductors with a minimum cross section area of 1mm2 16AWG Protecti...

Страница 24: ...mbly CH04A is designed for rack mount installation and will require 1U space in a standard EIA 19 or 23 rack CH04A chassis is delivered completely assembled however power modules and converter cards m...

Страница 25: ...ots numbered 2 through 4 may contain any other FRM220 Series In band Managed fiber media converter card Figure 2 4 NMC removal replacement in slot number 1 IMPORTANT In the FRM220 In Band Managed Rack...

Страница 26: ...An additional feature allows the Media Chassis to detect the working or failing status either of power module or any fan assembly in the unit and activate relays that can be used to control external a...

Страница 27: ...NMC has set Alarm 1 ON relay 1 is closed ALM 2 Red When On NMC has set Alarm 2 ON relay 2 is closed Figure Relays and LEDs Chassis Rear Description The rear panel holds the hot swappable power fan mod...

Страница 28: ...assis with random mix of line card types Heat Generation 120 BTU fully loaded chassis with random mix of line card types Compliance European Union EN55022 2006 Class A EN55024 1998 A1 2001 A2 2003 and...

Страница 29: ...s screwdriver for the 3mm and the 12 24 rack installation screws Wrist strap or other personal grounding device to prevent ESD occurrences Antistatic mat or antistatic foam to set the equipment on Sit...

Страница 30: ...gh a standard IEC C14 3 prong receptacle located on the rear of the module Any national power cord with IEC C13 line plug may be used to connect AC power to the power module With a DC24 or DC48 module...

Страница 31: ...er1 must contain an NMC card In a chassis where non managed line cards are employed cards that use DIP switch settings slot number 1 may then be used for a non managed media converter line card Line C...

Страница 32: ...slots available for installation of FRM220 Converter Cards in the FRM220 compact rack An SNMP Card is installed in the far left hand or first slot for local and remote management purposes Each FRM Car...

Страница 33: ...es The pluggable modules do not require any tools for removal and replacement Figure Chassis Rear View Chassis Physical Dimensions Figure Chassis Dimensions in millimeters Alarm 1 2 Relay Contacts Coo...

Страница 34: ...fully loaded chassis with random mix of line card types Compliance European Union EN55022 2006 Class A EN55024 1998 A1 2001 A2 2003 and EN60950 1 2001 FCC part 15 subpart B class A Reliability MTTB 6...

Страница 35: ...tatic foam to set the equipment on Site Preparation Install the FRM220 within reach of an easily accessible grounded AC outlet or three wire 48VDC Power return Earth Ground central office power The AC...

Страница 36: ...y be used to connect AC power to the power module With a DC module DC 48V is connected to the terminal block located on the rear of the module observing the proper polarity The FRM220 should always be...

Страница 37: ...n and another set of FAN Failure contacts normally open contacts for monitoring the power and fans condition of the FRM220 The alarm contacts may also be programmed through the management interface to...

Страница 38: ...s to the in of the slave using any standard Ethernet UTP straight cable with RJ 45 connectors Figure Cascade Ports Connections and ID assignment Pin No Signal Definition Direction Master Direction Sla...

Страница 39: ...ient temperature volts at frequencies of 50 60 Hertz The DC version supports either a standard 36 to 60VDC input voltage Only one power supply module is required to power a completely full rack When t...

Страница 40: ...eplace the card by reversing the procedure align in the slot groove and gently seat the card retightening the captive screw Figure Line card removal replacement NMC Card Installation Slot number 1 of...

Страница 41: ...ollow these communication parameters 115200 data rate 8 bits No parity bit 1 Stop bit No Flow Control Terminal Login Connect the console cable to PC and power up the FRM220 Start your favorite termina...

Страница 42: ...enters the menu to upgrade line cards in the FRM220 Setup the default gateway subnet mask and IP address as instructed by your network administrator After any TCP IP setting change the NMC must be re...

Страница 43: ...management IP address The following is an example of a Telnet screen It is exactly the same as a local serial console screen only it can be accessed remotely Web Based Manager The FRM220 NMC supports...

Страница 44: ......

Отзывы: