FRM220 Chassis Quick Installation Guide
11
Power Connection
The graphic below shows the power connections for the CH01M-AD, with one DC and one AC
power supply. When two supplies are connected, they are redundant, and the installed card device will
continue operation if only one supply is active.
The DC input utilizes a screw terminal block. Follow the proper polarity for DC, attaching the
negative DC voltage lead to the "-V" terminal and the positive DC voltage lead to the "+V" terminal.
Connect an Earth ground lead to the terminal marked "FG" (frame ground). DC voltage range input is
from 18 to 75VDC.
For AC power input, just firmly seat the IEC type power plug into the jack. The AC voltage range is
100-/- 10%. As long as the AC source is grounded, the ground will connect to the CH01/xx
chassis from the IEC connector.
Each power supply has a respective toggle switch which then sends the input power to the internal
supplies. The switch is OFF when set to "0" (zero) and is ON when switched to "1" (one).
Figure: CH01M-AD Power Connections
Operation & Storage Temperature :
- Operating Temperature -- -10°C
– 60°C
- Storage Temperature -- -20°C
– 70°C
- Humidity -- 10
– 90%
Dimension and Weight: ( W x D x H ) mm
- 135 × 200 × 32
- 730g (Single Power), - 775g (Dual Power)
WARNING
This is a Class A product. In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.
CE NOTICE
Marking by the symbol CE indicates compliance of this equipment to the EMC directive of the
European Community. Such marking is indicative that this equipment meets or exceeds the following
technical standards: EN 55022:1994/A1:1995/A2:1997 Class A and EN61000-3-2:1995, EN61000-3-