Chapter 2. Installation
2.5 Electrical Installation
2.5.1 Power connection, AC
For a model with AC power supply, AC power (100~240VAC) is supplied to the
FMUX04
through a becoming standard clover leaf 3-prong receptacle, located on the rear of the unit.
The
FMUX04
should always be grounded through the protective earth lead of the power
cable in AC installations.
AC Input
2.5.2 Power connection, DC
For a model with DC power supply, DC -24V (18~36VDC) or DC -48V (36~72VDC) is
connected to the detachable terminal block. The DC power connector uses a 'Molex' type
connector with detachable terminal block. Please take extra caution to observe the proper
polarity of the DC when wiring the connector. The
FMUX04
should always be grounded
through the protective earth lead via the frame ground connection for DC installations.
DC Input
18~36V
DC
36~72V
DC
Figure 2-3 : Supply connections, AC/DC models shown