16
CTC EcoPart XL
General
4.1.3 Control/power supply
CTC EcoLogic Pro
Up to 10 heat pumps can be connected to a CTC EcoLogic Pro, i.e. five
EcoPart XL units. The charge pumps in heat pumps 1 and 2 can then be
connected to the CTC EcoLogic Pro. A charge pump for heat pumps 3–10
must be installed and connected to the CTC EcoPart XL.
CTC EcoZenith v3
The PWM pump is connected to the CTC EcoPart XL and controlled by the
heat pump. If a 0–10 V pump from CTC or a non-speed-controlled pump is
used, see the manual for a CTC EcoZenith.
Standalone mode
The charge pump is connected to the CTC EcoPart XL and controlled using
the CTC Basic Display.