CTA
Instruction Manual
MPE
Reference: MT0027DA
This document may be modified without prior notice
17
Revision date: 11/05/06
Even partial reproduction is prohibited without authorisation in writing
12
Design specifications
Model MPE
004
006
008
010 015 020 025 030 040 050 060 075 100 125 150
Flow
rate*
m3/h 30 48 70 100 140 175 210 260 300 420 540 660 780 920 1020
Max. Pressure
bar
16
Connection BSP
½" ¾"
1"
1"1/2
2"
2"1/2
Power supply
230/1/50
Max. current
kW
0.3
0.5
0.7 0.75 0.84 1.05 1.1 1.3 1.5 1.85 2.2 2.4 2.8 3.2 3.50
Refrigerant Fluid
R134a
R407c
Load
gr
see on the data sticker at the back panel
HP Pressure switch
bar
18
26 (Manual Reset)
LP pressure
controller
bar -
1
(automatic)
Fan Pressure
Switch
bar
-
14 / 18
Dimensions
Width mm
430
465
575 740 740
740
Height mm
430
585 685 945 980
1200
Depth mm
430
470 540 600 760
1075
Weight
Kg 35 52 55 81 83 86 169 174 178 215 220 226 345 351 360
* Nominal flow rate expressed to 1 absolute bar, 20°C as stipulated in ISO 7183 IN the FOLLOWING conditions:
•
Air inlet temperature: 35°C
•
Operating pressure: 7 bars
•
Ambient temperature: 25°C
•
Relative humidity: 60%
•
Exhaust dew point: +3°C under pressure (-21°C at atmospheric pressure).