EZT-430i Communications Manual

                                           

 
 

Communication 

Basics 

                  

 

 

 

 

  CSZ 

EZT-430i 

REV 

3.2 

ASCII Character Chart 

Char Code  Decimal 

Binary  Hex Char Code  Decimal 

Binary  Hex 

NUL 

Ctrl @ 

00000000 

00 

Shift 2 

64 

01000000  

40  

SOH 

Ctrl A 

00000001 

01 

Shift A 

65 

01000001  

41  

STX 

Ctrl B 

00000010 

02 

Shift B 

66 

01000010  

42  

ETX 

Ctrl C 

00000011 

03 

Shift C 

67 

01000011  

43  

EOT 

Ctrl D 

00000100 

04 

Shift D 

68 

01000100  

44  

ENQ 

Ctrl E 

00000101 

05 

Shift E 

69 

01000101  

45  

ACK 

Ctrl F 

00000110 

06 

Shift F 

70 

01000110  

46  

BEL 

Ctrl G 

00000111 

07 

Shift G 

71 

01000111  

47  

BS 

Ctrl H 

00001000 

08 

Shift H 

72 

01001000  

48  

TAB 

Ctrl I 

00001001 

09 

Shift I 

73 

01001001  

49  

LF 

Ctrl J 

10 

00001010 

0A 

Shift J 

74 

01001010  

4A  

VT 

Ctrl K 

11 

00001011 

0B 

Shift K 

75 

01001011  

4B  

FF 

Ctrl L 

12 

00001100 

0C 

Shift L 

76 

01001100  

4C  

CR 

Ctrl M 

13 

00001101 

0D 

Shift M 

77 

01001101  

4D  

SO 

Ctrl N 

14 

00001110 

0E 

Shift N 

78 

01001110  

4E  

SI 

Ctrl O 

15 

00001111 

0F 

Shift O 

79 

01001111  

4F  

DLE 

Ctrl P 

16 

00010000 

10 

Shift P 

80 

01010000  

50  

DC1 

Ctrl Q 

17 

00010001 

11 

Shift Q 

81 

01010001  

51  

DC2 

Ctrl R 

18 

00010010 

12 

Shift R 

82 

01010010  

52  

DC3 

Ctrl S 

19 

00010011 

13 

Shift S 

83 

01010011  

53  

DC4 

Ctrl T 

20 

00010100 

14 

Shift T 

84 

01010100  

54  

NAK 

Ctrl U 

21 

00010101 

15 

Shift U 

85 

01010101  

55  

SYN 

Ctrl V 

22 

00010110 

16 

Shift V 

86 

01010110  

56  

ETB 

Ctrl W 

23 

00010111 

17 

Shift W 

87 

01010111  

57  

CAN 

Ctrl X 

24 

00011000 

18 

Shift X 

88 

01011000  

58  

EM 

Ctrl Y 

25 

00011001 

19 

Shift Y 

89 

01011001  

59  

SUB 

Ctrl Z 

26 

00011010 

1A 

Shift Z 

90 

01011010  

5A  

ESC 

Ctrl [ 

27 

00011011 

1B 

[ 91 

01011011 

 

5B 

 

FS 

Ctrl \ 

28 

00011100 

1C 

\ 92 

01011100 

 

5C 

 

GS 

Ctrl ] 

29 

00011101 

1D 

] 93 

01011101 

 

5D 

 

RS 

Ctrl ^ 

30 

00011110 

1E 

Shift 6 

94 

01011110  

5E  

US 

Ctrl _ 

31 

00011111 

1F 

Shift - 

95 

01011111  

5F  

SP 

SPACE 

32 

00100000  

20  

96 

01100000  

60  

Shift 1 

33 

00100001  

21  

97 

01100001  

61  

Shift ‘ 

34 

00100010  

22  

98 

01100010  

62  

Shift 3 

35 

00100011  

23  

99 

01100011  

63  

Shift 4 

36 

00100100  

24  

100 

01100100  

64  

Shift 5 

37 

00100101  

25  

101 

01100101  

65  

Shift 7 

38 

00100110  

26  

102 

01100110  

66  

‘ 

‘ 

39 

00100111  

27  

103 

01100111  

67  

Shift 9 

40 

00101000  

28  

104 

01101000  

68  

Shift 0 

41 

00101001  

29  

105 

01101001  

69  

Shift 8 

42 

00101010  

2A  

J 106 

01101010 

 

6A 

 

Shift = 

43 

00101011  

2B  

K 107 

01101011 

 

6B 

 

, 44 

00101100 

 

2C 

 

L 108 

01101100 

 

6C 

 

- 45 

00101101 

 

2D 

 

M 109 

01101101 

 

6D 

 

. 46 

00101110 

 

2E 

 

N 110 

01101110 

 

6E 

 

/ 47 

00101111 

 

2F 

 

O 111 

01101111 

 

6F 

 

48 

00110000  

30  

112 

01110000  

70  

49 

00110001  

31  

113 

01110001  

71  

50 

00110010  

32  

114 

01110010  

72  

51 

00110011  

33  

115 

01110011  

73  

52 

00110100  

34  

116 

01110100  

74  

53 

00110101  

35  

117 

01110101  

75  

54 

00110110  

36  

118 

01110110  

76  

55 

00110111  

37  

119 

01110111  

77  

56 

00111000  

38  

120 

01111000  

78  

57 

00111001  

39  

121 

01111001  

79  

Shift ; 

58 

00111010  

3A  

Z 122 

01111010 

 

7A 

; 59 

00111011 

 

3B 

 

Shift [ 

123 

01111011  

7B  

Shift , 

60 

00111100  

3C  

Shift \ 

124 

01111100  

7C  

= 61 

00111101 

 

3D 

 

Shift ] 

125 

01111101  

7D  

Shift. 62  00111110 

 

3E 

 

Shift ` 

126 

01111110  

7E  

Shift / 

63 

00111111  

3F  

DEL 

Delete 127  01111111 

 

7F 

 

Содержание EZT-430i

Страница 1: ...Table of Contents CSZ EZT 430i REVC i EZT 430i Single Dual Loop Controller User Communications Reference Manual ...

Страница 2: ...or WARNING safety statement Technical Assistance If you encounter a problem with your EZT 430i controller review all of your configuration information to verify that your selections are consistent with your application inputs outputs alarms limits etc If the problem persists after checking the above you can get technical assistance by dialing 1 513 772 8810 or by faxing your request to 1 513 772 9...

Страница 3: ...0 4 3 3 Transmitting and Receiving Messages 4 11 5 EZT 430i Data Registers standard serial interface 5 1 5 1 Control Registers 5 2 5 2 Automatic Program Registers 5 7 5 2 1 Starting an Automatic Program on EZT 430i 5 10 6 EZT 430i Simulated F4S D Interface Operation 12 6 1 F4S D Supported Control Monitoring Data Registers 12 6 2 F4S D Supported Profile Step Data Registers 17 6 2 1 Limitations of P...

Страница 4: ...o the application through software switches called events or be programmed to act as system alarm outputs EZT 430i can be operated in single set point or automatic program control mode Program entry is made easy through the use of copy paste and delete menu selections Programs can be copied to the external USB memory stick and then imported to another EZT 430i controller which eliminates the need ...

Страница 5: ...order mode for view only applications Email SMS FTP VNC and Web functionality standard Remote View Control using PC Tablet or Smartphone Detailed maintenance alarm monitoring and alarm history User configurable data logging and historical data viewer 4 level security with digitally signed audit trails and data files National time server connectivity with daylight savings Multi lingual user interfa...

Страница 6: ...h EZT 430i and the PC in order to convert the RS232 communications port to RS485 multi drop communications network for connecting multiple EZT 430i controllers on the PC communications link WARNING To avoid potential electric shock and other hazards all mounting and wiring for EZT 430i must conform to the National Electric Code NEC and other locally applicable codes Special expertise is required t...

Страница 7: ...ne EZT 430i to the next When using shielded twisted pair cable be sure to ground only when end of the cable preferably at the RS232 to RS485 network adapter Allowing any other portion of the cable shield to come in contact with ground or grounding both ends will cause ground loop currents to flow in that section of the cable which can cause communication errors ...

Страница 8: ...dard Code for Information Interchange called ASCII Bits and Bytes The word bit is simply the contraction of the words binary digit A bit is the basic unit in ASCII It is either a 1 or a 0 A byte is a string of eight bits that a computer treats as a single character ASCII can use a single byte to represent each letter of the alphabet each digit and each punctuation mark we use ASCII The ASCII code ...

Страница 9: ... 01011000 58 EM Ctrl Y 25 00011001 19 Y Shift Y 89 01011001 59 SUB Ctrl Z 26 00011010 1A Z Shift Z 90 01011010 5A ESC Ctrl 27 00011011 1B 91 01011011 5B FS Ctrl 28 00011100 1C 92 01011100 5C GS Ctrl 29 00011101 1D 93 01011101 5D RS Ctrl 30 00011110 1E Shift 6 94 01011110 5E US Ctrl _ 31 00011111 1F _ Shift 95 01011111 5F SP SPACE 32 00100000 20 96 01100000 60 Shift 1 33 00100001 21 a A 97 01100001...

Страница 10: ...ce that a character is coming and a stop bit tells it that a character is complete The start bit is always a 0 The stop bit is always a 1 The human speech equivalent of these bits could be a clearing of the throat to get someone s attention start bit and a pause at the end of a phrase stop bit Both help the listener understand the message A stop bit has a value of 1 or a mark state and it can be d...

Страница 11: ...n be connected to a master on a multi drop network up to 4000 feet long Wiring Most PCs have a standard EIA 232 port usually referred to as RS 232 In these instances you must use an interface converter to connect to an EIA 485 multi drop system The standards do not specify the wire size and type Use of 24 AWG twisted pair provides excellent results If shielded cable is used terminate the shield at...

Страница 12: ... enable this function The PC will not talk to the controller correctly without properly setting this Your converter may also require settings through dip switches to set up communications parameters like baud rate data bits start bits stop bits and handshaking The converter may also require a separate power supply Some converters get their power from the handshake lines of the PC If you rely on th...

Страница 13: ... Schneider created this protocol for process control systems called Modbus It has the advantage over other protocols of being extremely reliable in exchanging information This protocol works on the principle of packet exchanges The packet contains the address of the controller to receive the information a command field that says what is to be done with the information and several fields of data Th...

Страница 14: ...gned char char_ptr Start at the beginning of the packet char_ptr start_of_packet Initialize CRC crc 0xFFFF Loop through the entire packet do Exclusive OR the byte with the CRC crc unsigned int char_ptr Loop through all 8 data bits bit_count 0 do If the LSB is 1 shift the CRC and XOR the polynomial mask with the CRC if crc 0x0001 crc 1 crc 0xA001 If the LSB is 0 shift the CRC only else crc 1 while ...

Страница 15: ... between the host computer and multiple EZT 430i controllers on the serial link With a default timeout period in EZT 430i of 135ms it makes a total pause of 138ms minimum Thus after you receive a response from an EZT 430i controller at your PC you must wait a minimum of 138ms before sending the next command 4 Values containing decimal points such as process values and set points have the decimal p...

Страница 16: ...ess command registers and or data CRC Read Register s Command 0x03 This command returns from 1 to 60 registers This command is used for reading one or more data locations from EZT 430i Packet sent to EZT 430i controller address 1 byte read command 0x03 starting register high byte starting register low byte number of registers high byte 0x00 number of registers low byte CRC low byte CRC high byte P...

Страница 17: ...es in EZT 430i To set multiple values repeat the command for each data location Packet sent to EZT 430i controller address 1 byte write command 0x06 register high byte register low byte data high byte data low byte CRC low byte CRC high byte Packet returned from EZT 430i controller address 1 byte write command 0x06 register high byte register low byte data high byte data low byte CRC low byte CRC ...

Страница 18: ... byte number of registers to write high byte number of registers to write low byte number of data bytes data high byte data low byte register n data high byte register n data low byte CRC low byte CRC high byte Packet returned from EZT 430i controller address 1 byte write command 0x10 starting register high byte starting register low byte number of registers to write high byte number of registers ...

Страница 19: ...ate incomplete or failed transmissions To insure that the data you receive from a read command is correct and that the controller properly received a write command you must parse the controller s response and validate the return message to insure it is correct In order to validate that the message you received is correct you must caulate the CRC for the received message and compare it with the CRC...

Страница 20: ...smission or end of transmission characters if the serial port driver you are using does not support an interval timeout setting allowing you to automatically terminate a read after a specified time passes between bytes signaling the end of a message you must know how long the message will be that you are receiving That allows you to know how many bytes to read from your serial port and when you ha...

Страница 21: ...btain complete message Read in number of data bytes from message plus 2 additional CRC bytes Caulate the CRC for the message and compare to CRC received NO YES CRC s match Disregard message transmission error Enter recovery mode and resend command message in attempt to get valid response and or alert operator of a communication failure in order to take appropriate action Received message is valid ...

Страница 22: ... control register For the purpose of this manual parameters defined as bit oriented will have the function of each bit associated with the bit s index number in the data word The index number is equal to that of a typical array function Thus an index number of zero selects the first bit in the word LSB An index number of 1 selects the second bit in the word and so on This helps eliminate offset se...

Страница 23: ...tep Number R W 1 64 15 0x000F Automatic Program Operating Status R W B8 B8 16 0x0010 Program Name Characters 1 2 R B9 B9 17 0x0011 Program Name Characters 3 4 R B9 B9 18 0x0012 Program Name Characters 5 6 R B9 B9 19 0x0013 Program Name Characters 7 8 R B9 B9 20 0x0014 Program Name Characters 9 10 R B9 B9 21 0x0015 Program Name Characters 11 12 R B9 B9 22 0x0016 Program Name Characters 13 14 R B9 B...

Страница 24: ...0037 Alarm 5 Setpoint R W B12 B12 C1 56 0x0038 Alarm 6 Setpoint R W B12 B12 C1 57 0x0039 58 0x003A 59 0x003B Notes A R W Specifies readable writable data R specifies read only data and W specifies a write only control value B The range of certain parameters are dependent upon system options Consult the following range tables for information regarding the use of these parameters Reading bit oriente...

Страница 25: ...ve Bit4 Alarm 5 Active Bit5 Alarm 6 Active Bit6 Bit15 Not Assigned B5 Parameter Value Description Bit0 Loop 1 Manual Mode Bit1 Loop 2 Manual Mode Bit2 Bit15 Not Assigned Parameter Value Description 0 EZT 430i Online 1 Offline Program Download in Progress The status of this register should be used for information only as a means of determining if the system is ready for operation Note If either bit...

Страница 26: ...emble the ASCII characters in order from low to high byte starting with register 16 in order to assemble the automatic program name Store Test Note that null characters are not used in the program name A space 0x20 will be used is used in place of a null character to maintain the 14 character name length if the program name is not 14 characters long Note Auto tune may not be available depending up...

Страница 27: ...tive Bit13 Event 1 On Bit14 Event 2 On Bit15 Event 3 On B11 Parameter Value Description 0 No Error 4 Illegal Setup Values 10 Comm Error Bad Function Code 11 Comm Error Register Out of Range 14 Comm Error Write Read Only Data 15 Comm Error Out of Range Data 25 Holdback Time Out 26 Auto Tune Error 27 Input Type Requires Calibration 29 EEPROM Error 30 Cold Junction Failure 39 Sensor Break 40 A to D F...

Страница 28: ...gram step consists of 14 data registers The program must be written one step at a time using a multiple write command 0x10 to write the data for all 14 registers at once This allows programs to be stored as two dimensional arrays of which code can be written to simply index through the array step by step and transmit the program file to EZT 430i The first 14 registers of the program contain specif...

Страница 29: ...p Number must be offset by 1 when writing step data to EZT 430i Steps 1 64 will be sent with the step number as a value of 0 63 1 offset All remaining steps of the program follow the same format and data structure as is represented for step one above Up to the following 882 registers are used to contain the additional step data of the program as required for steps 2 through 64 Since few if any pro...

Страница 30: ...its hour on a dual loop system Since step time is defined by the ramp rate and the change in set point the program will get out of sync between each loop causing an automated program run error Note The last step of an automatic program must be an end step If the last step is not an end step the program will not run correctly and or a program download error will occur and the program will not opera...

Страница 31: ... sent registers 100 113 EZT 430i then begins looking for the number of steps of the program to be sent as was set in register 106 As each step is received it increments the count Once all steps have been received EZT 430i downloads the program to the loop controller program memory During this transfer register 0 will be set to 1 to indicate that the process is taking place Once the register value ...

Страница 32: ...1 second pause between write commands Send program data 100 thru 113 1 second pause Send step 1 data 114 thru 127 1 second pause Send step 2 data 128 thru 141 1 second pause Send last step data Is EZT 430i online 0 0 NO Set program start step 14 1 64 YES Set program to run 15 0 Done 1 second pause EZT 430i begins program download NO Write error during program download YES 20 second pause EZT 430i ...

Страница 33: ...tions registers see the Series F4S D User s Manual available from Watlow s website http www watlow com downloads en manuals Series 20F4SD_Rev 20H pdf 6 1 F4S D Supported Control Monitoring Data Registers The following table of data registers represents active functional data registers for the F4 interface that are used by EZT 430i for control monitoring While EZT 430i provides the full register ba...

Страница 34: ...ar Alarm 2 Key Press Simulation W B6 B6 332 0x014C Silence Alarm 2 Key Press Simulation W B6 B6 602 0x025A Set Point Low Limit Analog Input 1 R 32768 32767 C1 603 0x025B Set Point High Limit Analog Input 1 R 32768 32767 C1 606 0x025E Decimal Point Analog Input 1 R 0 3 608 0x0260 Process Units Analog Input 1 R B7 B7 612 0x0264 Set Point Low Limit Analog Input 2 R 32768 32767 C1 613 0x0265 Set Point...

Страница 35: ...Event Output 1 10 characters R B9 B9 3110 thru 3119 0x0C26 thru 0x0C2F Name Digital Event Output 2 10 characters R B9 B9 3120 thru 3129 0x0C30 thru 0x0C39 Name Digital Event Output 3 10 characters R B9 B9 3130 thru 3139 0x0C3A thru 0x0C43 Name Digital Event Output 4 10 characters R B9 B9 3140 thru 3149 0x0C44 thru 0x0C4D Name Digital Event Output 5 10 characters R B9 B9 3150 thru 3159 0x0C4E thru ...

Страница 36: ... 1 Current Profile Status R 32768 32767 C1 4123 0x101B Set Point Channel 2 Current Profile Status R 32768 32767 C1 4126 0x101E Jump Count Current Profile Status R 1 10000 Notes Parameters descriptions with Watlow F4 designations of channel 1 input 2 etc refer to EZT 430i data values for loop 1 or loop 2 A R W Specifies readable writable data R specifies read only data and W specifies a write only ...

Страница 37: ...99 B9 Range limited to standard printable ASCII characters 0 9 A Z etc B10 Parameter Value Description 1 Ramp Time 3 Soak 4 Jump 5 End Parameter Value Description 0 Temperature 3 Process units Note Auto tune may not be available depending upon the loop configuration If auto tune operation is not available auto tune will automatically turn off after being set The Watlow F4 contains multiple PID set...

Страница 38: ... non supported functions so a special profile editor is not required For the proper method of downloading profiles to an F4 controller reference the Profile Programming Procedures in section 7 Communications of the Watlow F4S D User Manual Register Address Parameter Description Data D Range E F Type Low High Unit 4000 0x0FA0 Profile Number R W 1 1 4001 0x0FA1 Profile Step Number W 1 64 4002 0x0FA2...

Страница 39: ...ak Steps W 0 1 4049 0x0FD1 Guaranteed Soak Channel 2 Ramp Soak Steps W 0 1 4050 0x0FD2 Jump to Profile Jump Step 4051 0x0FD3 Jump to Step Jump Step W 1 64 4052 0x0FD4 Jump Repeats Jump Step W 1 999 4060 0x0CSZ End Action End Step 4061 0x0FDD End Idle Setpoint Channel 1 End Step W 32768 32767 F2 4062 0x0FDE End Idle Setpoint Channel 2 End Step W 32768 32767 F2 Notes D R W Specifies readable writabl...

Страница 40: ...s of Profile Download Operation IMPORTANT Please Read The section covers the rules of use when sending F4S D based profiles to the EZT 430i controller These rules must be followed in order to insure proper profile operation especially when using the Profile Editor tool of WatView software WatView s operation can not be altered to comply with the manner in which EZT 430i operates so it is up to the...

Страница 41: ...automatically configures itself to use the best time format based on the programming for all ramp and soak steps For example if all ramp steps have only entries for minutes and seconds all hour entries are 0 EZT 430i will select minutes seconds for the ramp step time format However if a single ramp step has a non zero entry for hours it will use the hours minutes status registers for operation Thi...