![CSS i-Control Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/css/i-control/i-control_operational-and-maintenance-manual_2692956019.webp)
i
-Control User Manual
When you issue the ARP –S
command in Windows, “The
ARP entry addition failed: 5"
message displays.
Current logged in user does not
have the correct rights to use
this command on this PC.
A user with sufficient rights
needs to complete the task for
user rights have to be adjusted.
When you attempted to assign
an IP address to
i-
Control via the
ARP method, the “Press Enter to
go into Setup Mode” error
displayed. Now when you Telnet
to
i-
Control, the connection fails.
When you Telnet into port 9999
and do not press Enter quickly,
the server will reboot, causing it
to lose the IP address.
Telnet back into Port 1. Wait for
it to fail, then Telnet to port 9999
again. Make sure you press
Enter quickly.
When you click on Enable or
Disable you get one of the
following error messages on the
status bar
Status: Disabled; - Internal
Circuitry Error 0001
Status Enabled; - Internal
Circuitry Error 0002
Status: Enabled; - Internal
Circuitry Error 0003
Status: Disabled; - Internal
Circuitry Error 0011
Status: Disabled; - Internal
Circuitry Error 0012
Status Enabled; - Internal
Circuitry Error 0013
Internal circuitry may have been
damaged.
Contact CSS technical staff for
assistance.
5.1 Technical
Support
If you are unable to troubleshoot
I-
Control
by using the above table (Table 2) or if you cannot
fix your error, you may contact CSS technical support at
Email: [email protected]
Telephone: 03-9419 3955
Please have the following details when you contact CSS technical staff
Model of product
Serial
number
Date of purchase
Clear definition of problem
Steps taken so far to fix problem
i
-Control User Manual
- 12 -
30/04/2004