i
-Control User Manual
2. Open a Telnet connection to port 1. The connection will fail quickly, but the unit
will temporarily change its IP address to the one designated in this step.
Eg: telnet 192.168.1.220 1
3. Finally, open a Telnet connection to port 9999, and press Enter within three
seconds to go into setup mode. If you wait longer than three seconds, the unit will
reboot. If this happens go back to step 2 and start again.
Eg: telnet 192.168.1.220 9999
4. Set all required parameters by following the instructions given by the menu. Most
importantly set a static IP address. Once this is completed you may use the web
browser configuration to make further changes. Save settings before exiting.
Note:
The IP address you just set is temporary and will revert to the default value when the i-
Control's power is reset unless you log into
i-
Control configuration and store the changes
permanently. Refer to the configuration interface on section 3.1 for instructions on
permanently configuring the IP address
.
2.3.1.3
Using a Web Browser
Connect
i
-
Control to the network using the RJ45 Ethernet connections and apply A/C power.
You need to have a Java Runtime Environment version 1.4.2 installed on your system. Read
install_notes.txt for further details on how to install the Java Runtime Environment.
Open your default web browser and direct to the following IP address of
i
-
Control.
http://192.168.1.220/config.html
(replace the IP address with your IP address)
Note:
If DHCP was used,
you will need to identify the IP address by supplying the serial
number of the device (MAC address) to your network administrator. If you used ARP and
Telnet (Further details on section 2.3.1.2) you would know the IP address already.
We
recommend that you use an appropriate static IP address given by your network
administrator.
You will be directed to a login page. Enter the password to login to
i
-
Control configuration and
click OK. The factory default password is “password”.
Follow instructions given by section 3.2.
Note:
Passwords on
i
-Control are case sensitive.
i
-Control User Manual
- 5 -
30/04/2004