CSS i-Control Скачать руководство пользователя страница 1

 

 
 

 

i

i

-

-

C

C

o

o

n

n

t

t

r

r

o

o

l

l

 

 

 

 

O

O

p

p

e

e

r

r

a

a

t

t

i

i

o

o

n

n

a

a

l

l

 

 

&

&

 

 

M

M

a

a

i

i

n

n

t

t

e

e

n

n

a

a

n

n

c

c

e

e

 

 

M

M

a

a

n

n

u

u

a

a

l

l

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Document Revision CSS

i

C 10/03 

i

-Control Version 1.00 

Содержание i-Control

Страница 1: ...i i C Co on nt tr ro ol l O Op pe er ra at ti io on na al l M Ma ai in nt te en na an nc ce e M Ma an nu ua al l Document Revision CSSiC 10 03 i Control Version 1 00...

Страница 2: ...he Open Group Windows 95 Windows 98 Windows 2000 Windows NT and Windows XP are trademarks of Microsoft Corp Netscape is a trademark of Netscape Communications Corporation Java is a trademark or a regi...

Страница 3: ...ment in a residential area may cause interference in which case the user at his or her own expense will be required to take whatever measures may be required to correct the interference Date Revision...

Страница 4: ...Declaration of Conformity Manufacturer s Name Address Computer Support Systems Pty Ltd 373 Johnston Street Abbotsford VICTORIA 3067 Australia Product Name Model i Control Version 1 00 i Control User...

Страница 5: ...terial and workmanship for a period of one year from the date of initial purchase This warranty is voided if the customer uses i Control in an unauthorized or improper way or in an environment for whi...

Страница 6: ...is product should not be placed in a built in installation unless proper ventilation is provided 6 Do not allow anything to rest on the power cord Do not locate this product where the cord will be abu...

Страница 7: ...tion Indicator 3 2 3 I CONTROL CONFIGURATION 4 2 3 1 Assigning of an IP Address 4 2 3 1 1 Using DHCP 4 2 3 1 2 Using ARP and Telnet 4 2 3 1 3 Using a Web Browser 5 3 I CONTROL WEB INTERFACE 6 3 1 I CO...

Страница 8: ...abled web browser i Control is password protected and hence secure Typical applications of i Control Power down telephony equipment remotely when not required and power up when required Read the statu...

Страница 9: ...or else UDP Ports 30718 30704 must be available Otherwise you will not be able to detect or communicate with any of the i Control devices on the network To configure go to the Control Panel go to Net...

Страница 10: ...ect the RJ45 telephone cables as illustrated above 2 2 4 Power Connection Indicator The red LED Indicator next to the phone line connections shows that i Control is active The green LED is lit when te...

Страница 11: ...s default IP address of 0 0 0 0 DHCP has been enabled If your server is DHCP enabled i Control will be allocated with an automatic IP address gateway address and a subnet mask from the DHCP server wh...

Страница 12: ...ion 3 1 for instructions on permanently configuring the IP address 2 3 1 3 Using a Web Browser Connect i Control to the network using the RJ45 Ethernet connections and apply A C power You need to have...

Страница 13: ...i Control control interface by typing the IP address in the address bar of your browser Eg http 192 168 1 220 Alternatively you may configure your WINS Windows Internet Name Service to provide a name...

Страница 14: ...onfigure the parameters of the device Device Settings Device Name Allows you to enter a 32 character name for your i Control This name will be displayed on the i Control Control web interface to easil...

Страница 15: ...on Level The factory default password is set to be password We recommend that you change it to a desired password with at least four characters Note i Control passwords are case sensitive The password...

Страница 16: ...o i Control devices at the same time using the same PC If a second user attempt to log into an i Control device on use it will indicate that the device is busy by redirecting you to a different web pa...

Страница 17: ...Network Interface RJ45 Ethernet 10Base T or 100Base TX Auto sensing LED indication 10Base T 100Base TX Activity Full half duplex Network Compatibility Ethernet Version 2 0 IEEE 802 3 Operating Tempera...

Страница 18: ...face i Control web interface is a single user system When you load the IP address on your browser you are directed to a i Control busy web page Your computer is not able to connect to ports 30718 77FE...

Страница 19: ...ickly When you click on Enable or Disable you get one of the following error messages on the status bar Status Disabled Internal Circuitry Error 0001 Status Enabled Internal Circuitry Error 0002 Statu...

Отзывы: