10
- Start Up Procedure -
- Disinfection -
For disinfection of your unit, please follow the Sani-System Procedure on the back of the packet provided.
- Filling The Brine Tank With Salt -
To expect a high level of performance and reliability, a salt manufactured specifically for water softeners must be used.
Salt of this grade is virtually free from dirt and other particulates that would eventually cause the softener to malfunction.
A pellet type salt is recommended, although any high quality water softener salt (such as solar salt) will suffice. If iron is
present in raw water, use of iron inhibiting salt is recommended. The salt level will decrease after each regeneration cycle.
Consequently, the salt compartment will need to be checked and replenished periodically.
1. Fill the brine tank or salt compartment with water softener salt as described above. This will be approximately 250
pounds of salt. (150 lbs. for cabinet models.)
Warning:
Do not fill salt above level of the brine well.
2. Replace brine tank lid.
- Final Check -
1. Be certain the bypass valve is in the SERVICE position.
2. Make sure the power supply is connected to an uninterrupted 115-volt outlet.
3. Check that the time of day is set
4. Double check regeneration schedule.
5. Make final check for leaks!
6. Fill out warranty card online at www.csiwater.com
7. Leave all manuals with unit.
- Operation, Care and Cleaning -
When the bypass valve is in the SERVICE position (position of bypass lever is parallel to the inlet / outlet piping), water
is directed through the water softener. Water may be bypassed by turning the lever to the bypass position (position of
bypass lever is at right angles to inlet / outlet piping). Water to the home will bypass the softener and be untreated.
You should manually bypass the softener if :
1. The outside lines do not bypass the water softener and water is to be used for lawn sprinkling or other similar uses.
2. Servicing the water softener.
3. A water leak from the water softener is evident.
4. Shock treating water well and piping with chlorine or other disinfectant.
- Extra Regeneration -
If soft water demands are unusually heavy, an extra regeneration can be initiated manually :
- To Skip A Regeneration -
1. For vacations or extended periods of absence, the power supply can be disconnected from the control valve. It is
recommended that the 9-volt battery be removed.
2. Upon return, plug in cord and reset the time of day. Replace 9-volt battery.