![CSI CARDPIN1 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/csi/cardpin1/cardpin1_installation-manual_2692608045.webp)
Installation Guide
Proximity Readers
CSI Readers
39
3.
Connect the green wire (
Data-0
) from terminal 5, TB2 of the ARE-142 to terminal
5 on the breakout box or DPU-7920.
4.
Connect the orange wire (LED Green) from terminal 7, TB2 of the ARE-142 to
terminal 7 for Green LED operation.
5.
Connect the brown wire (LED Red) from terminal 8, TB2 of the ARE-142 to
terminal 6 for Red LED operation.
6.
Connect the black wire (Ground) from terminal 9, TB2 of the ARE-142 to terminal
8 of the breakout box or DPU-7920.
7.
Connect the cable shield to terminal 9, TB2 of the ARE-142.
Figure 23. ARE-142 Cable Output Connections
12VDC Linear Power
+
–
1
2
3
4
5
6
7
8
Black
Green
Shield
To DPU-7910A
Series Controller
White
Brown
1 2 3 4 5 6 7 8 9 10
Data 1
Data 0
Beeper In
LED Green
LED Red
DC PWR In (-)
DC PWR In (+)
Brown
Black
White
Green
Blue *
Orange
Shield
TB2
INPUT/OUTPUT
READER
A B C D E F
Antenna
Beeper Out
Red LED Out
Greed LED Out
Antenna PWR (-)
Antenna PWR (+)
Blue
Green
Brown
White
Black
Red
To Proximity
Reader Models
(PR-103, -105,
-120, -122)
Shield
TB1
Red
Indala ARE-142
Orange
* Blue wire not
connected to
Breakout box.
Содержание CARDPIN1
Страница 5: ...Installation Guide CSI Readers v Specifications 45 Index 49...
Страница 58: ......
Страница 59: ......