8.1 PREINSTALLATION
Before installing the stove, check that everything has been prepared.
Find below a quick checklist, for the complete information always refer to the pre-installation card.
Check that:
- the surface supporting the stove is level and cannot be affected
by the heat;
- if the floor does not withstand the weight of the stove, a 4mm-thick
metal sheet platform in the right size must be placed in between,
with insulating material, to be applied on the floor, of mineral ori-
gin (rock wool) and with a rated density exceeding 80 kg/m
3
.
- if the stove is installed on a wooden floor, we recommend a pre-
cautionary insulation of the support base with a 2mm-thick metal
sheet bigger than 50mm, all inside the unit.
- the fume outlet tube must exceed 80 mm in diameter.
- minimum dimensions have been complied with.
- In case of installation near flammable or combustible walls, keep
a safety distance of at least 30 cm on both sides and on the back.
Avoid leaving any type of combustible or flammable material
within 1 meter from the front of the unit.
- there is sufficient ventilation (0.5 m
2
minimum);
- an appropriate flue pipe for the discharge of the fumes has been
provided outside the installation area;
- a circuit breaker has been installed upstream that supplies the
stove and is triggered as required;
- there is no flammable material around the installation area.
The unit has been designed to be installed within the area it will serve.
As to positioning, the installer must comply with the minimum dis-
tances from the walls and surrounding material.
The surrounding spaces will also be used as easy access in case of
maintenance (see figure).
250 cm min
100 cm min
100 cm min
100 cm min
100 cm min