![CS THERMOS Murano 15/18 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/cs-thermos/murano-15-18/murano-15-18_instructions-manual_2692459020.webp)
20
cod. 6118005 ed. 06-2021
TECHNICAL DATA
UNITS OF
MEASUREMENT VENEXIA 15 VENEXIA 18 VENEXIA 21 VENEXIA 25
THERMAL POWER INPUT
(pellets)
kW
16.5*
18.4*
20.8*
25.6*
THERMAL POWER OUTPUT
(pellets)
kW
15.4*
17.0*
19.8*
24.0*
THERMAL POWER OUTPUT TO THE WATER
(pellets)
kW
13.6*
15.3*
18.0*
22.1*
Combustion EFFICIENCY
(pellets)
%
93.3*
92.5*
95.0*
93.4*
CO (13% O
2
) RATED POWER
g/Nm
3
0.16
0.21
0.07
0.08
CO (13% O
2
) REDUCED POWER
g/Nm
3
0.27
0.27
0.32
0.32
PP (13% O
2
)
mg/Nm
3
12.2
11.8
12.1
11.4
FUEL
Wood PELLET -
BIOMASS
Wood PELLET -
BIOMASS
Wood PELLET -
BIOMASS
Wood PELLET -
BIOMASS
CONSUMPTION AT MAXIMUM POWER
(pellets)
Kg/h
3.4 max**
3.8 max**
4.4 max**
5.2 max**
PELLET TANK CAPACITY
Kg
21
21
32
32
HEATABLE VOLUME
m
3
180-430***
180-470***
300-540***
300-640***
SMOKE OUTLET DIAMETER
mm
80
80
80
80
MAXIMUM SMOKE TEMPERATURE
°C
160
160
160
160
POWER SUPPLY
V
V230~ / 50Hz V230~ / 50Hz V230~ / 50Hz V230~ / 50Hz
MAXIMUM ABSORPTION
A
3
3
3
3
AVERAGE ELECTRICAL POWER IN
OPERATION
W
130
130
130
130
MAXIMUM ELECTRICAL POWER
W
700
700
700
700
BOILER MAXIMUM TEMPERATURE
°C
80
80
80
80
WATER MAXIMUM TEMPERATURE
°C
65
65
65
65
MAXIMUM OPERATING PRESSURE
bar
3
3
3
3
BOILER WATER CONTENT
l
32
32
52
52
BOILER NET WEIGHT
Kg
220-250
220-250
270
270
MINIMUM DRAUGHT REQUIRED
Pa
6
6
6
6
ENERGY CLASS
A++
A++
A++
A++
ENVIRONMENTAL QUALITY CLASS
(Ministerial Decree 186)
4 stars
4 stars
5 stars
4 stars
The data relating to the production of hot water were measured with the setting of the hot water temperature at 55°C,
with the cold water inlet temperature at 15°C and with the boiler at maximum power.
* The fire and rated power as well as the efficiency are measured in a lab test in optimal installation conditions.
** The data was recorded in a lab test in optimal conditions. Hourly consumption can vary according to the type of
pellets used and the installation.
*** The heatable volume is subject to variation according to installation conditions, type of house insulation and
external climatic conditions connected with the geographic location.
N.B.: The fuel humidity must not exceed 25%.