![CS THERMOS BIOHYDRA Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/cs-thermos/biohydra/biohydra_instruction-manual_2692453027.webp)
ENGLISH
26
ASH SC R APER (m ode l TESI H 20 )
At least once a week, remove the top protection panel and move from bottom to top t he cleaning lever
situated on the left side of the boiler (Fig. A), in such a way as to drop all the ash in the tray below. Aft er
cleaning, empty the ash tray.
Pe rform this cle a ning fre que ntly to a void boile r’s ove rhe a ting.
H EA RT H DO OR G LASS
The glass mounted in the hearth door is ceramic, and therefore resistant to high temperatures. To clean, use a
non abrasive dry cloth with specific liquid for glass cleaning.
Should it be damaged (e. g. chipped) it is rec ommended to have it replaced immediately by an authorised
technician before starting up the machine
DO N OT a tte m pt to re pa ir da ma ge d gla ss: a s the re is a risk of e x plosion during fu nctioning !
FLU E
To ensure that the machine works well, at least onc e a week, open, and when needed, clean t he " T" at t he
base of the fumes conduit and the horizont al portion of tube, if there is one.
The vertical fumes conduit and the entire flue must be checked and cleaned at least once a year. We
recommend the use of a specialised technician for a thorough and professional cleaning.
COM BUSTI ON AI R INT AK E
Monthly ins pect the air intake tube positioned under the start-up resistors to ensure it is not blocked by any
foreign material. If required, remove or suck out the dirt.
CH ECK M AG N ESIUM A NO D E
At least once a week, remove the top protection panel and, using a hex wrench, unscrew the magnesium
anode placed on the top of the sanit ary wat er tank. Examine the wear and, should it be worn-out, replace it
immediat ely to prevent failures due to corrosion.
GEN ER AL EN D OF S EAS ON CL EA NIN G
E very two months empty the pellet tank and clean out all accumulat ed saw dust.
After use, at the end of the season, clean and check all the parts indicat ed above, remembering to disconnect
the power supply of the boiler for increased safety.
It is advisable to check and clean the machine at least once per year by an authorised technician to ensure
correct functioning.
It is re com m e nde d, w he n re quire d, to che ck lubrica tion of the fue l loa ding a uge r bronze be a rings.
A
B