8. ELIMINATING FUMES DISCHARGE 

 

 

Fumes  discharge  must  comply  with  regulations  in  force  and  must  therefore  be  brought  above  the  roof.  The 

discharge  tube  must  be  made  out  of  smoot h  steel  with  silicon  washers  and  not  be  corrugated  flexible  type.  

Furthermore  it  must  be  positioned  externally  and  not  in  closed  or  semi-closed  spaces.  For  example:  garages, 

narrow  corridors,  under  closed  roofs  or  any  other  place  where  fumes  may  collect  in  case  of  leaks.  When 

connecting the boiler t o a flue, make sure, wit h a  professional chimney sweep, that the  flue is perfectly whole.. 

Oppositely it is absolutely obligatory to encase the existing  flue with material  which is suitable enough to ensure 

correct  functioning  (see  fig. 7)  The  flue  must  not  lean  against  the  fan.  It  is  necessary  to  assess  the  layout  and 

structure  of  the  house  once  the  flue  has  been  installed  via  walls  and  the  roof,  to  ensure  that  installation  has  

been done correctly and is in conformity with fire safety regulations.  You should also check: the internal section 

of the  flue, that there are  no  obstructions or  material used to  build it, the height, the  fittingness of the stack and 

the possibility to realise  vent holes.  

 

 

 

TYPE OF  TUBES USED FOR FLUES  

Rigid painted steel tubes (at least  1.5 mm thick)

 

,  or stainless steel ones (at least 0.5  mm thick), can  be  used.  

The male/female coupling collars must be superimposed by at least 40mm. 

 

 

 

DIAME TE R OF  THE FLUE  TUBE  

The  diameter  of  the  tubes  depends  on  the  type  of  system.  The  boiler  has  been  designed  for  tubes  with  an 

80mm diameter, as shown in the table, however in some cases 100mm is advisable. If 100 mm diameter tubing 

is necessary, connect it to the boiler using a "T" pipe connection using a 

ø

 80 - 

ø

 100 pipe  fitting. (see  fig. 8) 

 

 

FLU E

 

DIAM ET ER

 

OPINION

 

Tube length less than 5 m

 

80 mm

 

Correct 

 

Tube length more than 5 m

 

100 mm

 

Mandatory

 

For installations at an altitude of more than 
1200 m a.s.l.

 

100 mm

 

Recommended

 

 

Note: f or each 90° curve add 1 m and f or each 45° a dd ½ m. The lengths indicated on the table are only  relevant for the vertical portion. 

 

Horizonta l pa rts m u st no t e x cee d 2 m  in le ngth. 

It is PR OHI BITED to in sta ll air locks or  va lve s tha t could ob str uct  the  pa ssa ge  of  sm oke . 

 

It  is  obligatory  to  use  a  " T"  connection  tube  (see  fig.8)  with  an  inspection  plug,  as  a  connection  between  t he 

boiler  and the  flue,  which  will allow both the collection  of soot  that is  deposited inside the tubes  and periodical 

cleaning of t he  flue, without the  need to dismantle. Since the  fumes are  under light pressure,  ensuring that t he 

plug  for  cleaning  the  flue  is  perfectly  airtight  is  mandatory  and  it  must  be  the  same  after  each  inspection.  One 

must  remember  put  it  back  as  it  was  originally  and  check  the  condition  of  the  gasket.  Verify  that  the  various  

tubes are connected properly, as instructed by the manufacturer.   

It is strongly advised not to place tubes horizontally, but if absolutely necessary make sure they are placed  with 

an angle of at least 5%. 

If  a  t raditional  flue  is  used  it  is  possible  to  connect  without  the  need  for  a  " T"  connection  tube  but  you  must 

check that the flue has a bow for collecting  ash. 

It is advisable connect to the boiler with a horizontal track that is not more than 1m long.  

If  proper tube lengths are obeyed, the flue should have a  draught between 6 and 8 Pa.  

Do not change flue tube size in the middle of the route and especially after a bend or a horizontal portion. Verify  

that there are no constrictions in the discharge conduit or in the  flue.  

 

Содержание BIOHYDRA

Страница 1: ...INSTRUCTION MANUAL INGLESE BIOHYDRA BIOHYDRA MAXI BIOHYDRA MAXI 28 BIOHYDRA COMFORT TESI H2O...

Страница 2: ...the end of its working life the product must not be disposed of with household waste but be taken to a special differentiated waste collection center or to a dealer providing this service To dispose o...

Страница 3: ...t smells during functioning may be caused by the type of pellets used Possible noises during functioning are normal caused by the settlement of assembled parts Store bags of fuel at least 1 metre away...

Страница 4: ...orrosive gas reducing machine performance release polluting substances into the atmosphere and window incrustation Regulations on this matter have established that products using this type of fuel mus...

Страница 5: ...tem return 3 4 5 Boiler return 3 4 6 Circulator 7 Safety valve discharge 3Bar 8 Boiler discharge cock 9 Expansion tank 10 System flow 3 4 11 Hot water outlet 3 4 Comfort model 12 Cold water inlet 3 4...

Страница 6: ...ENGLISH 5 EXTERNAL DIMENSIONS BIOHYDRA Model BIOHYDRA MAXI Model 1245 590 630 scarico fumi output tube sortie fum es 900 640 1325 420 scarico fumi output tube sortie fum es...

Страница 7: ...H 6 BIOHYDRA COMFORT Model POSTERIOR VIEW OF BIOHYDRA COMFORT 900 640 1 325 5 50 250 250 11 5 23 0 sc arico fumi output tube sortie fum es D 80mm 140mm 80mm 200mm 120mm 180mm 270mm 650mm 800mm 1080mm...

Страница 8: ...GLISH 7 BIOHYDRA MAXI 28 Model POSTERIOR VIEW OF BIOHYDRA MAXI 28 900 640 1325 550 210 210 100 260 scarico fumi output tube sortie fum es D 100mm 140mm 200mm 270mm 650mm 800m m 1080mm 1065m m 10 4 5 7...

Страница 9: ...irculator 7 Safety valve discharge 3Bar 8 Boiler discharge cock 9 Expansion tank 10 System flow 3 4 EXTERNAL DIMENSIONS TESI H2O Model 1285mm 960mm 350mm scarico fumi flueheader sortie fum es scarico...

Страница 10: ...T TAN K C APACITY K g 26 70 70 70 26 HEATED VOLUME m3 300 380 300 380 400 500 300 380 220 300 S MOKE OUTLET DIAMETER mm 80 80 100 80 80 MAXIMU M S MOKE TEMPE RATURE C 160 160 160 160 160 ELECTR ICAL P...

Страница 11: ...SYSTEM AND THE BOILER AT EVERY FILLING CONNECT THE SAFETY VALVE DRAIN AND BRING IT OUTSIDE THE BOILER A DIRT SEPARATOR WITH MAGNET MUST BE INSTALLED ON THE RETURN CIRCUIT TO PROTECT THE BOILER S INTE...

Страница 12: ...mestic hot water production layout CIRCUITO RISCALDAMENTO COLLETTORE USCITA ACQUA CALDA SANITARIA ENTRATA ACQUEDOTTO CARICO IMPIANTO CIRCOLATORE HEATING SYSTEM HOT WATER OUTLET COLD WATER INLET DOMEST...

Страница 13: ...TARY WATER TANK SHOULD IT BE WORN OUT REPLACE IT IMMEDIATELY TO PREVENT FAILURES DUE TO CORROSION CIRCUITO RISCALDAMENTO COLLETTORE CIRCOLATORE CARICO IMPIANTO USCITA ACQUA CALDA SANITARIA ENTRATA ACQ...

Страница 14: ...nal contact must be covered with tiles or at least well insulated The stack must be wind resistant with an internal section that is equal to that of the chimney a useful section at least twice the siz...

Страница 15: ...y connect it to the boiler using a T pipe connection using a 80 100 pipe fitting see fig 8 FLUE DIAM ETER OPINION Tube length less than 5 m 80 mm Correct Tube length more than 5 m 100 mm Mandatory For...

Страница 16: ...s plants wood or elements that could be visually damaged walls windows within 3m of the flue WARNING Seeing that regulations regarding installation of pellet fuelled boilers are constantly being updat...

Страница 17: ...plaque electric power nominal voltage etc that the plant has a sufficient earth connection according to nominal regulations in vigour earth connection is obligatory by law the power cable should never...

Страница 18: ...ENCODER CLOCK BATTERY BOILER CIRCULATOR DIVERTER VALVE IGNITION RESISTOR CRUCIBLE MOTOR COMBUSTION FAN DISPLAY LOAD AUGER MOTOR MIXING AUGER MOTOR BOILER PRESSURE SWITCH AIR PRESSURE SWITCH BOILER SAF...

Страница 19: ...or combustible walls keep a safe distance of 30cm from the rear and sides of the machine Avoid leaving any type of flammable or combustible materials within 1m of the heat waves from the glass window...

Страница 20: ...ols phase with fire pot cleaning before loading fuel Charged Start up phase with fuel load in the burner while supplying power to the resistors at the same time Pause Pause while awaiting flame St fir...

Страница 21: ...ate an homogenous mixture The menu LOAD allows to vary the quantity of combustible to be loaded and it is subdivided into 3 levels of increa se and 3 levels of decrease each level consists of 0 2 se c...

Страница 22: ...r yes ON00 00 OFF00 00 ON00 00 OFF00 00 ON00 00 OFF00 00 ON00 00 OFF00 00 ON00 00 OFF00 00 Press to modify Press to modify Press to modify Press to modify Press to modify Press to modify Press to modi...

Страница 23: ...afety thermostat clean the inside of the stove reset the thermostat and restart the stove Thermostat auger Intervention on the part of the fuel auger safety thermostat clean the inside of the stove re...

Страница 24: ...r fig B using the flexible pipe supplied fig E to connect to your vacuum cleaner To remove any encrustation scrape the inside of the wheel holes fig C with the tip of the supplied accessory fig F remo...

Страница 25: ...er from under the burner Empty out all the ash taking care that there are no hot ashes fig A Carefully remove all ash from the bottom to avoid malfunctionings fig B Place the ash drawer back in its se...

Страница 26: ...l all ash has fallen into the below collecting drawer Now remove the burst protecting plate by loosening the relative wingnuts B and suck all fuel residue present inside the fumes conduit C using the...

Страница 27: ...ertical fumes conduit and the entire flue must be checked and cleaned at least once a year We recommend the use of a specialised technician for a thorough and professional cleaning COM BUSTION AIR INT...

Отзывы: