41
code 6118250 iss. 10-2018
9.5
Alarm code list
For your safety, do not tamper with or modify any component of the equipment: the manufacturer does not
guarantee its correct operation, which can be very dangerous. In case of malfunction, problems or if a safety
device is triggered, please call authorized personnel. Anyway, all operations must be carried out with the
burner off and cooled down and with the power disconnected.
No.
DISPLAY
MEANING
10
fume motor
Fume motor not working: call for an authorized engineer
11
mixing auger
The mixing auger of the burner is not turning: check for any obstructions in the fuel pipe
or call for an authorized engineer
12
crucible
The burner crucible does not rotate: clean the burner and restart or call for an author-
ized engineer
20
1 res. start. KO
One of the ignition resistances is not working: call for an authorized engineer
21
2 res. start. KO
Both ignition resistances are not working: call for an authorized engineer
22
res. fault
The ignition resistances are always powered: call for an authorized engineer
30
fume probe
Fume temperature probe interrupted or not connected: call for an authorized engineer
31
room sensor
Temperature probe interrupted or not connected: call for an authorized engineer.
40
auger sensor
Fuel auger safety thermostat triggered: clean the stove interior, reset the thermostat
and restart the stove.
42
boiler sensor
Fume discharge safety thermostat triggered: clean the stove interior, reset the thermo-
stat and restart the stove.
50
pressure switch
Air pressure switch not working: call for an authorized engineer
60
black out
No power: clean the burner and restart it
61
Network frequency
Electric voltage frequency incorrect: call for an authorized engineer
62
Short circuit
Err.
Internal error of the electronic board: call for an authorized engineer
63
Short circuit
err.
Internal error of the electronic board: call for an authorized engineer
70
failed ign.
Failed ignition: clean the burner and restart it
71
flame OFF
The flame went OFF during operation: clean the burner and restart
72
fume overheating
Combustion fume overheating: clean every part of the stove and restart
73
continuous loading
Pellet loading motor operation fault: call for an authorized engineer
100
system cycle
Internal error of the electronic board: switch off and restart the stove
101
service
Stove maintenance warning: call for an authorized engineer
To reset the stove operation, keep button
pressed for 5 seconds.