32
code 6118250 iss. 10-2018
8.10 Air ducting in Arianna 10/12, Cortina 10, Sirmione 10/12 models
Before starting work on the burner, disconnect the stove from the mains and turn the circuit
breaker on the main panel to OFF.
The ducting kit must be installed by qualified engineers.
In the above models, it is possible to direct hot air to the back of the stove installing the appropriate kit.
For the installation, proceed as described:
- Remove the back of the stove
1
, the small side
2
and the large side
3
.
- Insert the ventilation kit
4
, matching it to the anchor holes
5
and fasten it with the screws.
- Make the electrical connection on the motherboard
6
and activate the channelling function via the software
menu.
- Close the sides
7
-
8
and the back of the stove
9
.
To guarantee the ducting is working, the length of the piping must NOT exceed 6 metres with two 90° elbows and
the useful diameter must be between 60 and 80mm. Shorten the linear length by 1m for each further 90° elbow.
Moreover the inside of the pipe must be smooth and consisting of a material withstanding at least 130°C.
1
2
3
4
5
If flammable walls are crossed, insulate the piping with insulating material with a thickness of at least 4cm.
During the installation, pay attention not to damage the electrical cable.