8.1 Pre-installation
Before installing the stove, check that everything has been prepared.
Find below a quick checklist, for the complete information always refer to the pre-installation card.
Check that:
- the surface supporting the unit is level and cannot be affected by
the heat;
-
if the floor does not withstand the weight of the stove, a 4mm-
thick metal sheet platform in the right size must be placed in
between, with insulating material, to be applied on the floor, of
mineral origin (rock wool) and with a rated density exceeding 80
kg/m3.
- if the stove is installed on a wooden floor, we recommend a
precautionary insulation of the support base with a 2mm-thick
metal sheet bigger than 50mm, all inside the unit.
-
The fume outlet tube must exceed 80 mm in diameter.
- minimum dimensions have been complied with;
-
In case of installation near flammable or combustible walls, keep
a safety distance of at least 30cm on both sides and on the back.
Avoid leaving any type of combustible or flammable material
within 1 meter from the front of the unit.
- there is sufficient ventilation (250 cm
2
minimum);
- an appropriate flue pipe for the discharge of the fumes has been
provided outside the installation area;
- a circuit breaker has been installed upstream that supplies the stove
and is triggered as required;
- there is no flammable material around the installation area;
As to positioning, the installer must comply with the minimum
distances from the walls and surrounding material.
The surrounding spaces will also be used as easy access in case of
maintenance (see figure).
250 cm min
5 - 30 cm min
100 cm min
30 cm min
30 cm min
8 - INSTALLATION
Indicative picture