17
-
Parameter checking
and press
to enter, press
and
to check d0-d11 value. Press
checking.
Code
Condition
Scope
Remark
d00
IPM mould temperature
0-120
℃
Real testing value
d01
Inlet water temp.
-9
℃
~
99
℃
Real testing value
d02
Outlet water temp.
-9
℃
~
99
℃
Real testing value
d03
Ambient temp.
-30
℃
~
70
℃
flash if Real value<-9
d04
Frequency limitation code
0,1,2,4,8,16
Real testing value
d05
Piping temp.
-30
℃
~
70
℃
flash if Real value<-9
d06
Gas exhaust temperature
0
℃
~
C5
℃
(125
℃
)
Real testing value
d07
Step of EEV
0
~
99
N*5
d08
Compressor
running
frequency
0
~
99Hz
Real testing value
d09
Compressor current
0
~
30A
Real testing value
d10
Current fan speed
0-1200 (rpm)
Real testing value
d11
Error code for last time
All error code
Remark:
d4: Frequency limitation code,
0: No frequency limit;
1: Coil pipe temperature limit;
2: Overheating or overcooling frequency limit;
4: Drive Current frequency limit;
8: Drive voltage frequency limit;
16: Drive high temperature frequency limit
7.2.6
Select
to exit
Содержание CHP075PX
Страница 1: ......
Страница 2: ...Please read and understand ALL the instructions before installation and use...
Страница 6: ...4 2 Dimension unit mm 2 1 Model CHP075PX CHP095PX...
Страница 7: ...5 2 2 Model CHP115PX CHP135PX CHP165PX 2 3 Model CHP205PX CHP255PX...
Страница 8: ...6 2 4 Model CHP305PX...
Страница 11: ...9 Dry contact timer connection Timer Dry contact pump connection Water pump...
Страница 32: ...30 10 Exploded view 10 1 Model CHP075PX CHP095PX...
Страница 34: ...32 10 2 Model CHP115PX CHP135PX CHP165PX...
Страница 36: ...34 10 3 Model CHP205PX CHP255PX...
Страница 38: ...36 10 4 Model CHP305PX...
Страница 42: ...40...
Страница 44: ...42...
Страница 45: ...43 4 Parameter checking and setting Click Parameter then enter the password 0757...
Страница 47: ...45...
Страница 50: ......
Страница 51: ...A0211MPX02...