Crystal Vision 

 

Introduction

 

1   Introduction 

The Indigo range comprises of four frame types, 4U frames for up to 24 

modules, 2U  frames for up to 12 modules, 1U frames for up to 6 modules and 

a 1U Desktop Box for up  to 2 modules. Each frame type has several front 

panel variants, being, either a passive  front panel, an active panel with controls 

and a display or a Statesman-enabled version  without controls or a display. 

Apart from the Indigo DT Desktop box, all the Indigo range  of frames has 

plug-in PSU modules. 

 

This manual is about the plug-in Indigo PSU modules fitted to 4U, 2U and 1U frames. 

 

The PSU-160i is an Indigo plug-in PSU module providing a power output 

of160 Watts.  The PS-80i is also available as a spare 80 Watts power supply 

for the Indigo 1-DP frame. 

 

All of the Indigo PSU’s have a built-in processor, which communicates with 

the front  panel display processor (referred to as a PIC) such information as 

power rail voltage  levels (+5.75V and –6.0 V) and the PSU fan speed. The 

PSU also stores its own serial  number in the non-volatile memory. 

 

As the panel processor regularly receives status updates from the PSU 

processors about  power rails and fan speed, the front panel is then able to 

update its status LEDs and  control the alarm changeover relay according to the 

PSU condition. The relay contacts are  available on the Remote sockets at the 

rear of the frame. 

 

A cool operating temperature is maintained by a de-mountable fan that is 

positioned in  front of the PSU bay, drawing air through the slotting in the front 

panel. 

 

 

 

 

 

The Indigo 1 Crystal Vision frame with front control panel open

 

Indigo PSU Manual R1.2 

24/05/2010 

2

 

 

Содержание Indigo PSU-160i

Страница 1: ...go frames Includes PSU 160i and PS 80i Crystal Vision Ltd Lion Technology Park Station Road East Whittlesford Cambridge CB22 4WL England Tel 44 0 1223 497049 Fax 44 0 1223 497059 sales crystalvision t...

Страница 2: ...11 Reading LED status and active display messages 11 Replacing the mains input fuses 12 Indigo 1 DP 14 3 1 Frequently asked questions 15 4 Specification 16 Revision1 Indigo PSU 160i and dual PS 55i in...

Страница 3: ...80 Watts power supply for the Indigo 1 DP frame All of the Indigo PSU s have a built in processor which communicates with the front panel display processor referred to as a PIC such information as pow...

Страница 4: ...Crystal Vision Introduction The Indigo 2 Crystal Vision frame with front control panel open The Indigo 4 Crystal Vision frame with front control panel open Indigo PSU Manual R1 2 24 05 2010 3...

Страница 5: ...to qualified service personnel Apart from procedures described in this manual there are no user serviceable parts within the frame If the frame requires any other servicing it should be returned to th...

Страница 6: ...ey should both be the same version i e 2 x 160i The PSU 160i is not compatible with similar PSUs used on FR2AV and FR1AV Frames Indigo 1 DP power supply module The Indigo 1 DP is fitted with a pair of...

Страница 7: ...odules are mounted into the Indigo 1 DP frame by way of a retained mother board This mother board which remains in situ contains the CPU alarm relay and low voltage fusing for the frame bays It is als...

Страница 8: ...from GREEN to OFF every 2 3 seconds to warn that the switch is set to one instead of two Warning These servicing instructions are for use by qualified personnel only To reduce risk of electric shock d...

Страница 9: ...free the fan connector plugs the PSU fan will stop and the front panel PSU FAN LED will change from green to red Removing the PSU fan assembly Lower PSU 160i front view In addition to the PSU and fan...

Страница 10: ...switch behind the control panel is set correctly for the number of PSUs installed to prevent redundant PSU warnings Refitting the fan assembly To replace the PSU fan assembly proceed as follows Offer...

Страница 11: ...e 2 pin 23 Remote 2 pin 5 Indigo 2 Indigo 4 Fourth Power Supply Relay Connections Description Pin number relay common open on fault close on fault Remote 4 pin 14 Remote 4 pin 23 Remote 4 pin 5 Indigo...

Страница 12: ...low Change the panel fan Indigo 4 may be upper or lower fan PSU Fan Yell Grn None Normal operation Red Psu fan speed low Change PSU fan Indigo 4 may be upper or lower fan PSU Yell Grn None Normal oper...

Страница 13: ...more details The PSU 150i 48V line fuse is located internally to the PSU module Replacing this fuse will involve dismantling the module See replacing PSU 150i 48V fuse Note The red LED built into the...

Страница 14: ...awer and reconnect the power cords Rear connectors showing IEC mains inputs and fuse tray with main and spare fuses If a fuse blows repeatedly this indicates a fault either in the associated power sup...

Страница 15: ...the same type and rating 5A 250V time delay 3 1 Frequently asked questions Why is the display black and or no LEDs illuminated Check that at least one frame PSU is functioning Check that the frame is...

Страница 16: ...tch at the rear of the front panel is set correctly for the number of power supplies installed Why does the LOWER PSU LED flash from green to off This will occur if two PSUs are fitted when the Two On...

Страница 17: ...ion Indigo PSU General Dimensions 268mm x 105mm x 38mm Power requirements 85 to 264 volts 47 to 400Hz Operating conditions 0 to 40 degrees C non condensing Ventilation front to sides without air filte...