Trouble shooting

 

Crystal Vision 

 

Trouble shooting

 

 

the bottom of the  connector depression 

 

Remove the defective fuse and replace with either the spare fuse or 

with a 5A, 250V time delay fuse 

 

Replace the fuse drawer and reconnect the power cords 

 

 

 

Rear connectors showing IEC mains inputs and fuse tray 

with main and spare fuses

 

 

 

If a fuse blows repeatedly this indicates a fault either in the associated power 

supply  module or elsewhere. Return the frame and/or power supply to the 

manufacturer or dealer  for repair. 

Note: 

Replace the fuse only with one of the same type and rating (5A, 250V time delay). 

 

Indigo PSU Manual R1.2 

24/05/2010 

13

 

 

Содержание Indigo PSU-160i

Страница 1: ...go frames Includes PSU 160i and PS 80i Crystal Vision Ltd Lion Technology Park Station Road East Whittlesford Cambridge CB22 4WL England Tel 44 0 1223 497049 Fax 44 0 1223 497059 sales crystalvision t...

Страница 2: ...11 Reading LED status and active display messages 11 Replacing the mains input fuses 12 Indigo 1 DP 14 3 1 Frequently asked questions 15 4 Specification 16 Revision1 Indigo PSU 160i and dual PS 55i in...

Страница 3: ...80 Watts power supply for the Indigo 1 DP frame All of the Indigo PSU s have a built in processor which communicates with the front panel display processor referred to as a PIC such information as pow...

Страница 4: ...Crystal Vision Introduction The Indigo 2 Crystal Vision frame with front control panel open The Indigo 4 Crystal Vision frame with front control panel open Indigo PSU Manual R1 2 24 05 2010 3...

Страница 5: ...to qualified service personnel Apart from procedures described in this manual there are no user serviceable parts within the frame If the frame requires any other servicing it should be returned to th...

Страница 6: ...ey should both be the same version i e 2 x 160i The PSU 160i is not compatible with similar PSUs used on FR2AV and FR1AV Frames Indigo 1 DP power supply module The Indigo 1 DP is fitted with a pair of...

Страница 7: ...odules are mounted into the Indigo 1 DP frame by way of a retained mother board This mother board which remains in situ contains the CPU alarm relay and low voltage fusing for the frame bays It is als...

Страница 8: ...from GREEN to OFF every 2 3 seconds to warn that the switch is set to one instead of two Warning These servicing instructions are for use by qualified personnel only To reduce risk of electric shock d...

Страница 9: ...free the fan connector plugs the PSU fan will stop and the front panel PSU FAN LED will change from green to red Removing the PSU fan assembly Lower PSU 160i front view In addition to the PSU and fan...

Страница 10: ...switch behind the control panel is set correctly for the number of PSUs installed to prevent redundant PSU warnings Refitting the fan assembly To replace the PSU fan assembly proceed as follows Offer...

Страница 11: ...e 2 pin 23 Remote 2 pin 5 Indigo 2 Indigo 4 Fourth Power Supply Relay Connections Description Pin number relay common open on fault close on fault Remote 4 pin 14 Remote 4 pin 23 Remote 4 pin 5 Indigo...

Страница 12: ...low Change the panel fan Indigo 4 may be upper or lower fan PSU Fan Yell Grn None Normal operation Red Psu fan speed low Change PSU fan Indigo 4 may be upper or lower fan PSU Yell Grn None Normal oper...

Страница 13: ...more details The PSU 150i 48V line fuse is located internally to the PSU module Replacing this fuse will involve dismantling the module See replacing PSU 150i 48V fuse Note The red LED built into the...

Страница 14: ...awer and reconnect the power cords Rear connectors showing IEC mains inputs and fuse tray with main and spare fuses If a fuse blows repeatedly this indicates a fault either in the associated power sup...

Страница 15: ...the same type and rating 5A 250V time delay 3 1 Frequently asked questions Why is the display black and or no LEDs illuminated Check that at least one frame PSU is functioning Check that the frame is...

Страница 16: ...tch at the rear of the front panel is set correctly for the number of power supplies installed Why does the LOWER PSU LED flash from green to off This will occur if two PSUs are fitted when the Two On...

Страница 17: ...ion Indigo PSU General Dimensions 268mm x 105mm x 38mm Power requirements 85 to 264 volts 47 to 400Hz Operating conditions 0 to 40 degrees C non condensing Ventilation front to sides without air filte...

Отзывы: