Crystal Vision
Installation
Crystal Vision
Installation
Power supply relay connections
The power supply module has a changeover relay to indicate if the frame is in
an alarm state caused by a power supply problem, a fan stopping or an
overheating frame.
Pinout is as follows:
Indigo 2, Indigo 4 Upper Power Supply and Indigo 1 Relay Connections
Description
Pin number
relay common
open on fault
close on fault
Remote 2 pin 14
Remote 2 pin 23
Remote 2 pin 5
Indigo 2, Indigo 4 Fourth Power Supply Relay Connections
Description
Pin number
relay common
open on fault
close on fault
Remote 4 pin 14
Remote 4 pin 23
Remote 4 pin 5
Indigo 4 Lower Power Supply Relay Connections
Description
pin number
relay common
open on fault
close on fault
Remote 8 pin 14
Remote 8 pin 23
Remote 8 pin 5
Indigo 4 3rd Power Supply Relay Connections
Description
pin number
relay common
open on fault
close on fault
Remote 6 pin 14
Remote 6 pin 23
Remote 6 pin 5
Note:
The current though the relay contacts should be limited to a maximum of 200mA.
Indigo PSU Manual R1.2
24/05/2010
10