Crystal Vision
Installation
Indigo 4 User Manual R1.7
16
09/08/2012
Board settings
On the upper edge of the lower 4U front panel PCB can be found the config switches and
status LEDs.
4U lower board top-edge switches and LEDs
Frame Address
The frame address, which only relates to active panels such as the Statesman enabled or
active control panel, is set to give a frame or frame pair a unique address when used in
serial 422 connected systems. In a TCP system the frame address switch must be set to
zero.
Rotary switch
Position
Description
Frame Address
Normally zero
This is usually the address of the frame from 0 to 15.
Note:
Set this switch to position 0, unless multiple frames communicate with a single PC port
in a Statesman system, or if multiple control panels connect to a single frame via one
multi-drop cable.
Statesman will display the Hex switch settings 0 to E as frame addresses 1 to F. Switch
setting F will be displayed as frame address 10.
Status LEDs
These LEDs are useful for trouble shooting the network link. The link LED will be
illuminated whenever the frame is connected to a network. Should this LED not be lit
check the cable connection between the frame and network outlet. The data LED flashing
will indicate that communications between the frame and the network exists.
Description
Data
Flashing
This LED will flash to indicate activity.
Link
Normally lit
This LED will be lit whenever the frame is connected to an
Ethernet network.