15 issue 5
The foam seal provided must now be fitted to t
he
Outer Frame
of the fire as shown in
Fig 16:2
.
The fire can now be carefully fitted by guiding the gas
supply complete with Restrictor Elbow through the gas
entry hole in the rear of the fire.
If the wall is perfectly flat it is recommended the outer frame is fitted and sealed from the inside with
high temperature silicone ,fire cement or sand and cement
The outer frame must be sealed so no air can pull through it after installation all
the flue pull must be made through the fire diverter and from no other place ,
The fire should now be sealed to the sealing frame using
the screws provided.
Fit the Outer Trim (Black) to cover the sealing frame. It will
be necessary open the Glass Door to enable you to tilt the
Outer Trim to guide it around the Glass Door then fix with
the screws provided. See
Fig’s 16:3a & Fig 16:b
.
Fig 16:2
Fig 16:3a
Fig 16:3b
Make the final gas connection by sealing the
Restrictor Elbow to the Control.
Unseal the Restrictor Elbow and check the gas joint
for gas soundness.