background image

Pre-Planting Seed Calibration Process (using CAL TEST function)

This procedure is used prior to field operation.  These steps will determine a more accurate 

Meter Cal value for your exact drill settings with your seed. 

 

Preparation

1. Set the slot opening on each drill section for the desired crop.

2. Fill drill with seed.

3. Disconnect a few or all drop tubes on each section.

4. Position catch container under each drop.

Enter Calibration Mode (switch controller to hold and press the “CAL” button until the red light is solid)

1. Turn Rotary Position Switch to “Cal Test”, “Off” appears in the display, press “+” to activate the Calibration 

Test mode “1” appears in the display (a one (1) lb sample will be dispensed from each opener).

2. Turn Rotary Position Switch to “Test Speed”.

3. Use “+” to enter normal operating speed.

4. Turn Rotary Position Switch back to “Cal Test”.

5. Switch from the hold to the run position and turn all section on.  The “Cal Test” will begin.  The display will 

count up the measured sample weight and automatically turn off at one (1) lb.

6. Combine the samples and weigh, then calculate the average sample weight.

7. Adjust the controller measured weight (1 lb) to the actual average sample weight.  Use the “+” and “-“ buttons 

to adjust the weight.

8. Press and Hold “CAL” until red light is off to exit calibration. This saves the new calibration settings.

9. Re-run test to verify calibration is accurate.

10. Re-enter calibration mode and turn dial to Meter Cal.  Make a note of the Meter Cal for your drill and seed 

in the DrillMaster manual.

CrustBuster

DrillMaster Quick Start Guide

346-001150 

 

 

 

 

 

  Pg 8 

    

 

 

 

 

   Revised 4/2/2010

Содержание DrillMaster

Страница 1: ...REFERENCE MANUAL DrillMaster Grain Drill Section Controller www surefireag com ...

Страница 2: ...ng to the bottom connection 6 Install the switch harness connector into the mating connector gray tie on the console harness NOTE If using the included Power On Off switch instead of the ignition switch connection install the power switch as described above Connect the power switch cable connector 2 pin to the mating connector on the console harness Mounting the Run Hold Switch Kit Remove the moun...

Страница 3: ...e to the battery When routing cable to console avoid areas where the cable may be subjected to abrasion or excessive heat Attach the BLUE wire ground to a screw or bolt on the equipment frame See Illustration 3 Be sure there is a good metal to metal contact Connect the ORANGE wire to the positive battery terminal Connect the power to the DrillMaster console by plugging the 2 pin W P tower on the p...

Страница 4: ... Tractor Controller Wiring Layout To Run Hold Switch Gray Tie To Astro 5 Yellow Tie Controller to Hitch To Battery 10 Pin Harness on Drill CrustBuster DrillMaster Quick Start Guide 346 001150 Pg 4 Revised 4 2 2010 ...

Страница 5: ... also resets AREA counter 1 WEIGHT MINUTE Displays lbs of product dispensed per minute AREA HOUR Displays calculated Acres Hour RATE Displays application rate in lbs acre AREA TOTALS 1 2 3 Keeps a running count of the total acres worked May be reset Note WEIGHT and AREA counters work in pairs if WEIGHT counter 1 is reset it also resets AREA counter 1 DISTANCE Displays distance traveled in feet May...

Страница 6: ... one lb increments during operation in AUTO TARGET RATE Enter the value for the desired or Target Rate in lbs acre It can range from 0 00 to 99 999 This is the seeding rate the console will lock onto when operating in AUTO ROWS SECTION This displays the rows per section for the section selected Unused sections must be programmed to zero rows The DrillMaster can have up to three sections NOTE the c...

Страница 7: ...the WEIGHT MINUTE check the speed sensor connections sensor gap to target wheel and the Meter Cal value Proceed to the next step when you can increase and decrease the WEIGHT MINUTE reading using the and keys on the DrillMaster 9 Turn each section switch on and off Does each section turn on and off when commanded With any single section on is there a number displayed for WEIGHT MINUTE 10 Turn the ...

Страница 8: ...d from each opener 2 Turn Rotary Position Switch to Test Speed 3 Use to enter normal operating speed 4 Turn Rotary Position Switch back to Cal Test 5 Switch from the hold to the run position and turn all section on The Cal Test will begin The display will count up the measured sample weight and automatically turn off at one 1 lb 6 Combine the samples and weigh then calculate the average sample wei...

Страница 9: ...ured seed weight will accrue in the weight counter you reset in step 1 3 Find the total actual weight of seed dispensed 4 Enter Calibration mode by pressing CAL for 1 second Red light will come on steady 5 Turn dial to the Meter Cal position The current Meter Cal will be displayed 6 Push CAL key to toggle to the weight Use the and buttons to adjust the weight to the actual weight drilled The Drill...

Отзывы: