background image

Hydraulic Drive Meter Calibration Numbers

These are starting calibration values.  They can be refined for your drill and seed using the Pre-

Planting Seed Calibration Process or the In-Field Seed Calibration Process.

1. Turn your hydraulic valve on for the hydraulic drive.
2. Push the AUTO/MAN button until MAN is displayed 

on the DrillMaster. You are now in Manual mode.
3. Put the system in RUN. Turn the console switch to 

RUN and lower the implement to actuate the mercury 

Run/Hold switch mounted on the drill.
4. Turn Section 1 switch ON.
5. Turn dial to WEIGHT/MINUTE position. Is a 

number displayed? If so push the “+” button. Does 

the number increase? Push the “-” button. Does the 

number decrease?
6. If no reading in WEIGHT/MINUTE is the hydraulic 

drive turning.
7. If drive is not turning, check hydraulic connections 

and try hydraulic control lever in the opposite 

direction.
8. If drive is turning, but no reading on the WEIGHT/

MINUTE, check the speed sensor connections, 

sensor gap to target wheel and the Meter Cal value. 

Proceed to the next step when you can increase and 

decrease the WEIGHT/MINUTE reading using the “+” 

and “-” keys on the DrillMaster.

9.  Turn each section switch on and off.  Does each 

section turn on and off when commanded?  With any 

single section on is there a number displayed for 

WEIGHT/MINUTE.
10. Turn the dial to SPEED. Drive the tractor. Does 

the speed reading seem reasonable and correct? The 

ASTRO 5 will be a more accurate speed than an un-

calibrated tractor speedometer. You are now ready to 

test AUTO mode. You can drive the tractor and verify the 

system works correctly. 
11.  If you want to sit still, you can enter Calibration Mode, 

then turn the dial to TEST SPEED. Using the “+” key 

increase the speed to your operating speed. Turn the 

Run/Hold and section switches on. The system will now 

perform as if it is traveling at the speed you entered.

Initial Operation to Test DrillMaster Setup

First we will test the system in Manual Mode.

CrustBuster

DrillMaster Quick Start Guide

346-001150 

 

 

 

 

 

  Pg 7 

    

 

 

 

 

   Revised 4/2/2010

Содержание DrillMaster

Страница 1: ...REFERENCE MANUAL DrillMaster Grain Drill Section Controller www surefireag com ...

Страница 2: ...ng to the bottom connection 6 Install the switch harness connector into the mating connector gray tie on the console harness NOTE If using the included Power On Off switch instead of the ignition switch connection install the power switch as described above Connect the power switch cable connector 2 pin to the mating connector on the console harness Mounting the Run Hold Switch Kit Remove the moun...

Страница 3: ...e to the battery When routing cable to console avoid areas where the cable may be subjected to abrasion or excessive heat Attach the BLUE wire ground to a screw or bolt on the equipment frame See Illustration 3 Be sure there is a good metal to metal contact Connect the ORANGE wire to the positive battery terminal Connect the power to the DrillMaster console by plugging the 2 pin W P tower on the p...

Страница 4: ... Tractor Controller Wiring Layout To Run Hold Switch Gray Tie To Astro 5 Yellow Tie Controller to Hitch To Battery 10 Pin Harness on Drill CrustBuster DrillMaster Quick Start Guide 346 001150 Pg 4 Revised 4 2 2010 ...

Страница 5: ... also resets AREA counter 1 WEIGHT MINUTE Displays lbs of product dispensed per minute AREA HOUR Displays calculated Acres Hour RATE Displays application rate in lbs acre AREA TOTALS 1 2 3 Keeps a running count of the total acres worked May be reset Note WEIGHT and AREA counters work in pairs if WEIGHT counter 1 is reset it also resets AREA counter 1 DISTANCE Displays distance traveled in feet May...

Страница 6: ... one lb increments during operation in AUTO TARGET RATE Enter the value for the desired or Target Rate in lbs acre It can range from 0 00 to 99 999 This is the seeding rate the console will lock onto when operating in AUTO ROWS SECTION This displays the rows per section for the section selected Unused sections must be programmed to zero rows The DrillMaster can have up to three sections NOTE the c...

Страница 7: ...the WEIGHT MINUTE check the speed sensor connections sensor gap to target wheel and the Meter Cal value Proceed to the next step when you can increase and decrease the WEIGHT MINUTE reading using the and keys on the DrillMaster 9 Turn each section switch on and off Does each section turn on and off when commanded With any single section on is there a number displayed for WEIGHT MINUTE 10 Turn the ...

Страница 8: ...d from each opener 2 Turn Rotary Position Switch to Test Speed 3 Use to enter normal operating speed 4 Turn Rotary Position Switch back to Cal Test 5 Switch from the hold to the run position and turn all section on The Cal Test will begin The display will count up the measured sample weight and automatically turn off at one 1 lb 6 Combine the samples and weigh then calculate the average sample wei...

Страница 9: ...ured seed weight will accrue in the weight counter you reset in step 1 3 Find the total actual weight of seed dispensed 4 Enter Calibration mode by pressing CAL for 1 second Red light will come on steady 5 Turn dial to the Meter Cal position The current Meter Cal will be displayed 6 Push CAL key to toggle to the weight Use the and buttons to adjust the weight to the actual weight drilled The Drill...

Отзывы: