Crown Broadcast FM 20/100 W, user manual– 05/2013
Page 70
Crown Broadcast, a division of International Radio & Electronics Corporation 25166 Leer Drive, Elkhart, Indiana, 46514-5425 USA
Ph +1 (574) 262 8900
6.2.2. Measurement
commands
NAME
Access
(R/W)
Possible value on the serial
port of the unit
Comments
MEAS.12V
R
xx.x x=[0..9]
Measures the 12 V voltage
MEAS.5V
R
xx.x x=[0..9]
Measures the 5 V voltage
MEAS.AMB R
±[0..125]
Measures the ambient temperature from 0
to 125°C. "52"=>52°C.
MEAS.DEV.PEAK R -150,0…150,0
Gives the peak value for the signal deviation
in kHz
MEAS.DEV.RMS R
-150.0…150.0
Gives the average value for the signal
deviation in kHz
MEAS.N12V
R
-xx.x x=[0..9]
Measures the -12 V voltage
MEAS.PFWD R
[0..9999]
Measure of forward power. examples: "20"
or "300" => 300 W
MEAS.PREF
R
xxx.x x=[0..9]
Measure of reflected power: "20" => 2 W
MEAS.VSWR
R
XX.X X=[0..9]
VSWR measure "01.0" or "20.0"
MEAS.VSWRTRIP
[0..99]
Gives the number of reflected power safety
in the past hour