APPENDIX D: TROUBLESHOOTING
D.1. Calibration
!
Your transmitter is calibrated at the factory and
should not need to be recalibrated.
In case it become misadjusted, first contact Crown
Broadcast’s technical support department. They
may advise you to recalibrate the unit, in which
case you will be sent the calibration file.
Connect your module to a PC to be able to use the PC
application (see section 7). Once connected, launch the
application and:
Open the Calibration window using the
Tool/Calibration menu.
Click the “Load” button and select the .cal
calibration file supplied by Crown Broadcast.
Click the “Set” button to load the calibration file into
the unit.
D.2. Complete Reset of the Crown Broadcast FME
!
The reset procedure erases your whole configuration; however, the calibration is kept.
Connect a PC to the front panel serial port as described in section 6.
Send the command:
SYS.RAZ=RAZ
After the module has restarted, on the front panel:
Enter the transmitter’s nominal power (example 20 for
a Crown Broadcast FME 20 W).
For
Crown Broadcast FME 20 W only
, select Yes to
indicate the module acts as a central unit (mandatory
in the current version).
Set the CAN Id to 00
Exit the Init Config menu to return to standard menus.
T X P C A P
-> 2 0
I S C C U
-> Y E S
I D C A N
-> 0 0
I N I T C O N F I G
E X I T