WARNING
•
Failure to properly support a Maxi-Therm could result in property damage or per-
sonal injury.
•
Some localities may require this product to be braced, anchored, or strapped to pre-
vent it falling or moving during an earthquake. Consult the state or local authority
having juridication for more information.
CAUTION
Install the Maxi-Therm in a location where a leak in the tank, the connected piping,
or an open T & P valve will not damage the area adjacent to the heater or to lower
floors of the structure. When such locations cannot be avoided, install the Maxi-
Therm in a suitable drain pan connected to an adequate drain. This drain pan should
have a length and width at least 2” greater than the diameter of the Maxi-Therm.
18
IV. BEFORE STARTING INSTALLATION
1) Be sure that the planned installation is in accordance with all local codes. Also note that some jurisdictions
may not permit the installation of an MT079G or MT100G with a boiler having a gross output in excess of
200,000 BTU/hr. Consult the authority having jurisdiction before installing a MT079G or MT100G with a
boiler having an output in excess of 200,000 BTU/hr.
2) Read and understand all installation requirements in this manual.
V. LOCATING THE MAXI-THERM
1) Table 1 shows the weights of all Maxi-Therms filled with water. Make sure that the location chosen for the Maxi-
Therm is capable of supporting it.
2) Observe the recommended clearances shown in Figure 5. These clearances are needed to access the anode rod
and hand hole cover gasket for inspection and maintenance. The anode rod is located in the hand hole cover
on the MT040G and MT050G, so there is only a clearance requirement on the top of the Maxi-Therm. All
clearances not shown in Figure 5 are 0”.
IMPORTANT
Avoid rough handling when moving the Maxi-Therm to its final location. Rough han-
dling could damage the protective lining inside the tank .
Содержание MAXI-THERM MT040G
Страница 4: ...3 Figure 1b MT079G and MT100G General Configuration Figure 1a MT040G and MT050G General Configuration...
Страница 22: ...Figure 6 Boiler Side Piping Using Circulator Zones Figure 7 Boiler Side Piping Using Zone Valves 2 Way 21...
Страница 28: ...Figure 12 Basic Domestic Side Piping Figure 13 Domestic Side Piping Using a Mixing Valve 27...
Страница 30: ...Figure 15 Domestic Side Piping for Multiple Maxi Therms 29...
Страница 32: ...Figure 16 Non Priority Circulator Zoning Using Honeywell R845a s Figure17 PriorityCirculatorZoning 31...