17
Circulator
8.0 Gal/min
10.0 Gal/min
Taco007
8.2
7.3
Taco 008
9.8
7.2
Taco 0011
22.8
21.0
Grundfos UPS 15-42F
11.0
9.0
Grundfos UPS 26-64F
21.0
19.5
Grundfos UPS 26-96F
23.0
21.0
Available Head (ft w.c.)
Table 5: Selecting a Circulator
[a]
[b]
[c]
[d]
Fitting Description
8 Gal/min
10 Gal/min
MT040G Coil
1
2.60
2.60
MT050G Coil
2.60
MT079G Coil
4.40
MT100G Coil
5.70
1 ft 1" St. Pipe
10
0.05
0.08
0.50
1 ft 1-1/4" St. Pipe
6
0.02
0.03
0.12
1 ft 1-1/2" St. Pipe
0.01
0.02
1" 90 El
6
0.16
0.25
0.96
1-1/4" 90 El
3
0.06
0.09
0.18
1-1/2" 90 El
0.04
0.06
1" Run of Tee
0.05
0.08
1-1/4" Run of Tee
1
0.02
0.03
0.02
1-1/2" Run of Tee
0.01
0.02
1" Branch in Tee
0.26
0.41
1-1/4" Branch in Tee
2
0.08
0.13
0.16
1-1/2" Branch in Tee
0.05
0.08
1" Std. Ball Valve
0.12
0.19
1-1/4" Std. Ball Valve
0.06
0.09
1-1/2" Std. Ball Valve
0.02
0.03
Taco "Flo-Chek":
#220 (1")
1
2.18
3.41
2.18
#220 (1-1/4")
0.84
1.31
#222 (1-1/2")
0.44
0.69
Taco "Air Scoop":
#431 (1")
0.15
0.23
#432 (1-1/4")
1
0.05
0.08
0.05
Boiler (**)
1
0
0
ft wc.
Notes:
* Includes (2) 1-1/2 x 3/4 Bushings and (2) 1-1/2 x 1 Transitions
** The Pressure Drop Through Most Cast Iron and Steel Boilers can be Ignored
WORKSHEET #3: Pressure Drop Calculations Through M axi-Therm Zone
3.61
0.53
Total Head Loss Through Manifold Piping and Maxi-Therm Zone =
7.30
Pressure Drop (ft head)
at:
Quantity
Total
Allowance for Bushings and
Sudden Transitions (*)
1
0.53
0.83
Honeywell V8043F1101 Zone
Valve (Cv = 8)
2.31
Figure 4: Example of Use of Worksheet 3
Содержание MAXI-THERM MT040G
Страница 4: ...3 Figure 1b MT079G and MT100G General Configuration Figure 1a MT040G and MT050G General Configuration...
Страница 22: ...Figure 6 Boiler Side Piping Using Circulator Zones Figure 7 Boiler Side Piping Using Zone Valves 2 Way 21...
Страница 28: ...Figure 12 Basic Domestic Side Piping Figure 13 Domestic Side Piping Using a Mixing Valve 27...
Страница 30: ...Figure 15 Domestic Side Piping for Multiple Maxi Therms 29...
Страница 32: ...Figure 16 Non Priority Circulator Zoning Using Honeywell R845a s Figure17 PriorityCirculatorZoning 31...