thecrowgroup.com
Page | 46
Report Disarm
only after an Activation
If this option is on, the panel will not normally send an
Arm/Disarm signal to the monitoring company, however, if a
zone alarm occurs the panel will send a Disarm following the
disarming of the panel to show it has been turned OFF by a valid
user
No channel selected
Report Stay Disarm only
after an Activation
If this option is on, the panel will not normally send a Stay Mode
Arm/Disarm signal to the monitoring company, however, if a
zone alarm occurs the panel will send a Stay Mode Disarm
following the disarming of the panel to show it has been turned
OFF by a valid user
No channel selected
Report Access to
Program Mode
If this option is on the panel will report a Contact ID code to
indicate that either Client or Installer program Modes have been
accessed
All channels selected
Report Zone Restores
If this option is on the panel will report all zone restores. If this
option is turned off the panel will only report the alarms
All channels selected
Report Delinquent
If the panel has been configured for Delinquency monitoring and
an area has not been armed for the time set at, a Delinquency
Alarm will be sent to the Monitoring Station
All channels selected
Report Radio Battery
Low
If this option is on the panel will report a Battery Low from any
radio zones that have the battery status monitored
All channels selected
Report Supervised Radio
Alarm
If this option is on the panel will report a Supervised radio Alarm. All channels selected
Report Zone Sensor-
watch Alarm
If this option is on the panel will report a Zone Inactivity (Sensor-
watch) Alarm.
All channels selected
Report Latchkey Disarm
When this option is turned ON and the panel was armed in
Latchkey Report Mode, at Disarming by a non-latchkey user the
specified latchkey disarm report will be sent via voice or SMS
report channel to user, marked as latchkey mode user.
All channels selected
Report Communication
Interference Detected
If the radio receiver detects Communication Interference
(Jamming) of the radio frequency, the panel can report this
event to the monitoring station if this option is turned on
All channels selected
Report Output Fail
If this option is on and a fault is detected on the output, a report
will be sent to the monitoring station if Contact ID is set as the
reporting format
All channels selected
Report Tests
If this option is selected, the panel can send automatic test
connections, but if test connections are not required, they can
be disabled by turning this option off.
All channels selected
Report Stay Mode Zone
Alarms
If this option is on, the panel will report zone alarms in Stay
Mode
All channels selected