Zones
The SHEPHERD™ Panel supports up to 64 wireless zones: ISM zones and/or DECT Zones
We invite you to visit our website http://www.thecrowgroup.com for more information on our Two-Way wireless ISM and
DECT detectors range.
To configure Zones, click on the zone to display its related options.
Parameter
Description
Default Configuration
Name
Enter zone name
Add Zone
This option used for enrolling new device RF , DECT or
Extender and assign it to a zone and setting the device’s
configuration
Zone Status
Parameter
Description
Default Configuration
Zone is active
Activate or deactivate the zone, The panel will monitor the zone.
zone is activated
automatically right after
enrolling and learn a
new device
Stay mode zone
Zone will cause alarm if triggered when Stay Mode is armed. This
feature is normally used for arming just part of the alarm at night
time.
All zones selected
Is Two trigger zone
If this option is ON the zone will have to trigger twice within the two
trigger time before it will cause an alarm. If the zone does not trigger
a second time before the two trigger time expires, the count is reset
and it will take another two triggers to cause an alarm on this zone.
If more than one zone is set-up as a two trigger zone, then a single
trigger from two separate zones within the two trigger time can also
cause an alarm. If the zone becomes faulty and still open once
triggered at end of two trigger time period it will also cause an alarm.
No Zone selected
Exit delay zone
Zone should be closed for ready to arm. It will not cause an instant
alarm if triggered during the exit delay time.
All zones selected
Can Arm if Zone is not
Ready
Zone can remain open during arming and will cause alarm in case it
will remain open after the exit delay expired. This zone is named
"Low Security Zone".
No Zone selected