3
Installation instructions.
Selecting mounting location
The installation of the CSB-60 requires that the transmitter and the receiver face
each other, so that the two antennas may be correctly aligned.
The two units must be positioned in direct line at the edge of the area. Local
conditions of the protected zone must be free from obstacles like walls, fences,
trees and ditches or other microwave detectors and systems of anti-intrusion
surveillance.
In order to ensure suitable operation of the CSB-60 type of ground should be one of
the following: Asphalt, Cement, Soil, Clay, Gravel or Grass (mown).
Avoid the following locations.
Avoid installation of CSB-60 on the following type of ground: Thick vegetation,
Grass (unmown), Water, Sand and a Metal.
The ground must not have movable parts near the sensitive zone, any grassy areas
must be frequently mown, there should not be any flowing water, especially
longitudinally, ground where structural features may be changed.
The installation site should satisfy the following requirements (see fig. 1):
•
The surface of the site should be leveled with a maximum slope angle of 15°.
•
No obstacles as bushes or group of trees within a distance of 1m from the
centerline between two units.
•
Depth of snow on the ground should not be more than 0.5m.
•
Height of a grass on the ground should not exceed 0.3m. It is important to mow
the grass regularly to avoid its movement interfering with the microwave
signal.