Trouble shooting Chart 

Symptom (s) 

Possible Causes(s) 

Corrective Action(s) 

Power Indicator  
Light is off after 
turning on the 
power supply. 

1.The light is broken. 
2.Fuse is blown. 
3.Not 120V or 230V Input 
Voltage. 
4.Power supply switch is 
broken. 
5.Controlling board or cutter 
is damaged. 

1.Replace. 
2.Replace. 
3.Connect the 120V or 
230V Input cable. 
4.Replace. 
5.Examine and repair. 

Fan doesn’t work 
after turning on the 
power supply. 

1.Fan is damaged. 
2.Fan’s ground lead is 
broken. 
3.Fan’s blade is blocked 
4.Transformer is damaged. 

1.Replace. 
2.Examine and repair. 
3.Clean the block. 
4. Replace. 

Low Pressure 
Indicator Light is 
on 

1.No input compressed air 
2.Air/gas pressure valve is 
adjusted to 0 or broken. 
3.Air/gas pressure circuit is 
blocked 
4.Air/gas pressure valve is 
damaged 

1.Examine and repair. 
2.Adjust or replace. 
3.Clean the block. 
4.Replace. 

No Air/gas check 
function. 

1.Air/Gas valve is ruined. 
2.Air/Gas circuit is blocked. 
3.Air/Gas check switch is 
ruined 
4.Ground lead is broken. 

1.Replace. 
2.Clean the block. 
3.Replace. 
4.Examine and repair. 

Can’t cut or no 
high frequency 
output. 

1.Discharge gap is too big. 
2.High pressure mica 
capacitance damaged. 
3.Pilot transformer is 
damaged. 
4.Main controlling board is 
damaged. 
5.Ground lead is broken 

1.Adjust to suitable gap. 
2.Replace. 
3.Replace. 
4.Examine and repair. 
5.Examine and repair. 

No response after 
turning on the torch 
switch. 

1.Switch and ground-lead are 
broken. 
2.Switch board is broken. 
3.Main controlling board is 
damaged. 
4.Transformer is damaged. 
5.Ground lead is broken. 

1.Examine and repair or 
replace. 
2.Examine and repair or 
replace. 
3.Examine and repair or 
replace. 
4.Replace. 
5.Examine and repair. 

No response after  1.Power cord hooked up  1.Examine 

and 

repair. 

Содержание Invercut 40D

Страница 1: ...Invercut 40D WARNING Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating Failure to follow the safety rules and other basic safety precautions may result in serious...

Страница 2: ...unt the welder on a secure bench or cart that will keep the welder secure and prevent it from tipping over or falling 1 2 Your Welder s Condition Check ground cable power cord and welding cable to be...

Страница 3: ...ct all cables and cords for any exposed wire and replace immediately if found Use only recommended replacement cables and cords Always attach ground clamp to the work piece or work table as close to t...

Страница 4: ...lammable gaseous or liquid combustibles in them Welding creates sparks and heat that can ignite flammable and explosive materials Do not operate any electric arc welder in areas where flammable or exp...

Страница 5: ...cables on the same side of your body Shielding Gas Cylinders Can Explode High pressure cylinders can explode if damaged so treat them carefully Never expose cylinders to high heat sparks open flames m...

Страница 6: ...Power Supply 1ph 120V 230V 50 60Hz No load Voltage 320V 310 Output Range 16A 15 40A Duty Cycle 35 40A Air Pressure 4 5 CFM 60 PSI Power Switch 250VAC 30Amps Dimension L x W x H 400 x 150 x 290 mm Weig...

Страница 7: ...e back of the plasma cutter is in the ON position Work Indicator When cutting this light is on to show the unit is on working mode Protection indicator Light When the unit is in thermal overload is ov...

Страница 8: ...d 1 4 Aluminum 1 4 Copper 1 8 Brass 1 8 INSTALLATION 1 POWER REQUIREMENT AC single phase 120V or 230V 50 60HZ fused with a 40 amp time delayed fuse or circuit breaker is required DO NOT OPERATE THIS U...

Страница 9: ...extension cord over 25 ft in length 3 INSTALLATION OF THE CUTTING TORCH CONSUMABLES 3 1 Your torch should be fully assembled and ready to operate The below figure shows the components of the torch he...

Страница 10: ...the power switch of the cutter to observe if the operation is normal If it is normal the fan should start up and the Power Indicator Light should be on If there is no compressed air or the air pressu...

Страница 11: ...e on the work piece could cause the nozzle to stick reducing the smoothness of the cutting action creating an undesirable result Keep the torch s nozzle vertical against the work piece and watch to be...

Страница 12: ...r in wet moist environments Do not bend the torch cable sharply this may damage the air hose Nobody other than the operator should be allowed to access the working area Always turn off the power suppl...

Страница 13: ...re circuit is blocked 4 Air gas pressure valve is damaged 1 Examine and repair 2 Adjust or replace 3 Clean the block 4 Replace No Air gas check function 1 Air Gas valve is ruined 2 Air Gas circuit is...

Страница 14: ...roken 1 The tolerant voltage range is 100V 250V The machine will stop working and indicator will come on if the input power voltage is not between 120V and 230V AC Please check the voltage with a volt...

Страница 15: ...14 Plasma Cutter Operating Instructions and Parts Manual Plasma Cutter Invercut 40D...

Страница 16: ...IP 4 IP 5 ACS770 H1 1 G 2 C 3 E Q5 C16 2 R10 1 OUTAP R106 C11 R107 R96 RV2 RV3 C94 R110 RV4 G1 G4 E1 G2 G3 E2 PPC40 10 14B23 MAIN 01 QF GAS 1 2 3 FAN FAN1 1 2 CN3 1 2 CN1 1 2 3 CN4 CS CS RLY2 1 2 GUN...

Страница 17: ...16 Plasma Cutter Operating Instructions and Parts Manual Plasma Cutter Invercut 40D Spare Part List...

Страница 18: ...0070550047 Gas pressure regulating valve 1 13 11020020088 Pressure regulator connector 1 14 20050080006 Camber surface handle 1 15 12070024095 Solenoid Wiring Harness 1 16 11010010564 1 r e v o c l l...

Страница 19: ...18 Plasma Cutter Operating Instructions and Parts Manual Plasma Cutter Invercut 40D...

Страница 20: ...19 Plasma Cutter Operating Instructions and Parts Manual Plasma Cutter Invercut 40D...

Страница 21: ...1 R R RR e ve 14 2018 ee e e e e 2 1 e 0 4 e 5 CROSSFIRE ALL CROSSFIRE WELDERS CROSSFIRE WELDERS ee 1 800 5 4445 e...

Отзывы: