Crossfire 190CUB Скачать руководство пользователя страница 7

                                         

 

 

5

* There will be sparks flying during operating, keep distance between working field 

and vicinity.   

* Operating should be within duty-cycle. Over load will cause accelerated components 

aging and decreased use life, even machine damage. 

* Do not modulate or move the machine during operation. 

* Welders have strong electromagnetism and frequency interference, so keep away people with heart 

pacemaker or the articles which can be interfered by electromagnetism and frequency. 

* Do not squeeze or smite the welding cable. 

* Do not allow irrelevant people go to welding operation field. 

2.4. Safe Measures to be taken to assure the correct Installation and Position 

* Precaution must be taken to keep the operator and the machine from the foreign materials falling 

from up above.   

* The machine must be installed in the place where it can not be exposed to sun and rain. Also it 

must be stored in less humid place with the temperature range at 

10~40°C. 

* The machine should be placed at horizontal position, in case of turnover or shift.   

* There should be 50cm space about for the welding machine to have good ventilation.   

* Make sure that there is no metal-like foreign body to enter the welding machine 

* Make sure that there is no interference with the surrounding area at the installation site.   

* Take measures to prevent wind while operating in the strong wind since the welder is gas shielded.   

2.5 Safety Check 

Each item listed below must be carefully checked before operation:   

* Make sure that the welding machine has reliable earth connection.   

* Make sure input/output cable in good condition and no exposure. 

Regular check needs to be conducted by the qualified personnel after the welder has been installed 

over a period of six months, which involves as follows: 

        * Routine cleaning needs to be done to make sure that there is no abnormal loose parts happening in 

the welding machine. 

* The parts installed on the panel must guarantee that the welder works properly.   

* Check the welding cable to see if it can continue to be used before it is worn out.   

 

Notice: Cut off the power supply before opening the case to check. 

Please do not hesitate to contact us for technical assistance whenever you come across the problems 

you can not work out or you may deem difficult to fix.   

 

3.  Technical Specification

 

3.1 Environment to Which the Product is Subject 

* The surrounding temperature range:  when working: -5

~ +

40

                         

During transport or in storage: 

25

~ +

55

℃ 。

 

* Relative humidity:    when at 40

50%, 

when at 20

90%. 

*The height above the sea: below 1000m 
* Keep from raining when it is used outdoor. 

Содержание 190CUB

Страница 1: ...190CUB GASOLINE WELDING GENERATOR OPERATOR S MANUAL Operation Manual...

Страница 2: ...ma torch parts nozzle electrode diffuser cover are considered consumable items and are not covered under warranty 90 days Parts for Crossfire spool guns welding carts and welding cabinets This warrant...

Страница 3: ...Operator s self protection 2 3 Operator s notice 2 4 Safe Measures to be taken to assure the correct Installation and Position 2 5 Safety Check 3 Technical Specification 3 1 Environment to Which the...

Страница 4: ...engineering and also could be applied to enterprise and public institution CUB 190 Gasoline welding generator function features 1 Power output 115 230V 60Hz 2 2KW 2 Welding current 55A 190A 3 Electrod...

Страница 5: ...ammable materials at least 11 meters Prevent sparks to cracks or shady place Fire extinguisher should be allocated at working area No welding sealed vessel Acid liquor in battery may cause textile to...

Страница 6: ...body without insulation No welding vessel with flammable and explosive materials or sealed vessel No operating at very humid filed Prevent flying sparks from hurting people No touching on any positio...

Страница 7: ...ng machine Make sure that there is no interference with the surrounding area at the installation site Take measures to prevent wind while operating in the strong wind since the welder is gas shielded...

Страница 8: ...l a u n a M e p y t g n i t r a t S g n i k r o w s u o u n i t n o c s r u o h 8 e p y t k r o W Gasoline generator 0 4 4 H C r e l h o K l e d o M r e d n i l y c e l g n i S e p y T fan cooled fou...

Страница 9: ...el 4 1 Control panel parts name and function Item Name Qty Function 1 Start handle 1 Start engine refer to engine manual 2 Fuel tank cap dipstick 2 Fuel charging and fuel quantity measurement 3 Engine...

Страница 10: ...mained quantity of fuel 11 Fuel tank cover 1 Fuel tank cover 4 2 Control Panel Drawing 1 5 Operation environment 5 1 Outdoor operation 5 1 1 The welder must be loaded in the place where less dust 5 1...

Страница 11: ...d be reliably grounding 6 5 Check to make sure no oil leakage If leaking please contact us or seller immediately 6 6 Check whether the parts are loose Check and make sure not loosen of bolts nuts and...

Страница 12: ...or operation 10 1 Prepare machine and all relative work 10 2 Choose correct welding cable and connect the power supply Connecting lug and terminal must be reliable in case of poor contact burning Cabl...

Страница 13: ...e table 3 Besides Daily check others by hour Regular check is important to gasoline engine function and lifetime Check items and agenda as below check and clean Replace Table 3 Note means check should...

Страница 14: ...filter is blocks up Clean or replace Take off the air is bad Let out the air Fuel cylinder type winding not working Examine the fuse If it breaks off please replace a new one Check and replace the cy...

Страница 15: ...Rotor cable short circuit Repair Engine cable burning Repair Can not reach the rated voltage Over load Reduce loading to rated value Low rotate speed Adjust accelerograph to rated speed Generator cab...

Страница 16: ...p e c e r k c o l t s i w t V 0 3 2 5 1 2 e l c a t p e c e r V 5 1 1 6 1 2 r e k a e r b t i u c r i C 7 1 1 r e k a e r b t i u c r i C 8 1 2 r o t c e n n o c k c i u Q 9 1 1 r o t s i s e R 0 2 1...

Страница 17: ...y ventilation and free from corrosive gas or dust The tolerable temperature ranges from 25 with no cooling water 55 and the relative humidity can not be more than 85 17 Quality Guarantee Users are adv...

Страница 18: ...16 Drawing 2 Main circuit chart...