Instruction Manual

            

Model 3116-T31-148   

   

 

Multi-Band, Block Translator

 

  

April 2015,   Rev. C

   

MENU

EXECUTE

MODEL 3116

C

ROSS 

T

ECHNOLOGIES INC.

BAND 1 6.425 > 4.200 GHz 

G=+00  TRANS = 2.225 GHz

 

MUTE

REMOTE POWER

ALARM

MULTI-BAND TRANSLATOR

Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be 

reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating 
the equipment.

When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, 

equipment serial number, and a description of the part.

C

ROSS 

T

ECHNOLOGIES, INC.

6170 Shiloh Road

Alpharetta, Georgia 30005

(770) 886-8005 

FAX  (770) 886-7964

Toll Free  888-900-5588

WEB  www.crosstechnologies.com 

E-MAIL  [email protected]

Содержание 3116-T31-148

Страница 1: ...to Cross Technologies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies...

Страница 2: ...s are warranted against defective materials and workmanship for a period of one year after shipment to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cr...

Страница 3: ...ernet M C or via the Monitor Control connector The 3116 T31 148 is powered by a 100 240 10 VAC power supply and housed in a 1 75 X 19 X 17 rack mount chassis MENU EXECUTE MODEL 3116 CROSS TECHNOLOGIES...

Страница 4: ...y LO Characteristics 0 5 dB Frequency Response 40 MHz 2 dB Frequency Response Band 40 dBC 10 dBm In 0 dBm Out Spurious Inband in Level 45 dB 60 typical In to Out Isolation Minimum 20 to 40 dB 1 1 dB G...

Страница 5: ...47 63 Hz 30 watts maximum Power Ethernet and RS232C 9600 Baud RS485 Optional Remote Gain Band Select internal 10 MHz frequency via Ethernet M C or Monitor Control Connector Gain Band 10M Frequency 10...

Страница 6: ...rnal reference x 1 to select internal reference where aaCEx Set External Reference x 0 to unmute the output x 1 to mute the output where aaCMx Set Mute Range 20 to 40 in 1 1 dB steps e g 11 11 0 dB xx...

Страница 7: ...ff z 1 mute is on Returns aaSAwxyz where aaSA Unit Status x 3 if in auto select mode x 3 if band is selected in 13 75 to 14 85 GHz out 11 7 to 12 8 GHz x 2 if band is selected in 7 90 to 8 40 GHz out...

Страница 8: ...4 5 VDC power supply provides power for the assemblies The 3116 T31 148 can be secured to a rack using the 4 holes on the front panel Figure 2 0 shows how the 3116 T31 148 is assembled POWER SUPPLY VC...

Страница 9: ...ale connector J7 J2 J7 ETHERNET CONNECTION Option W8 RJ45 Ethernet Connector RF MON J1 RF IN 5 925 6 425 GHz 7 90 8 40 GHz 13 75 14 85 GHz SMA female connector See Table 2 2 for other options J1 RF IN...

Страница 10: ...wer DS1 REMOTE LED Yellow LED indicates remote operation S2 VERT TOGGLE Vertical toggle switch that controls values in the Menu items when in program mode Does not function in the normal display mode...

Страница 11: ...output level is always within the range of 60 to 0 dBm See Table 2 0 6 Select either INT for internal 10 MHz ref or EXT for external 10 MHz 2 to 8 dBm reference that is inserted at J3 7 AC Fuse The f...

Страница 12: ...l RJ 45 cable Use any PC on the LAN to connect to the 3116 T31 148 2 5 2 Ethernet Configuration Each 3116 T31 148 must be configured with an appropriate IP address Netmask and Gateway assigned by your...

Страница 13: ...and Gateway address with delimiter dots example 192 168 192 47 2 5 3 Webpage M C Enter the following address in a web browser to access the M C Webpage http ip address of 41xx serial 0 setup htm where...

Страница 14: ...g Windows XP s Hyper Terminal utility Start the Hyper Terminal application and select New Connection from the File drop down menu The next screen is a Connect To dialog box Select TCP IP Winsock from...

Страница 15: ...P community read and write strings After setting your desired community strings you will be prompted to Enter IP addresses for SNMP traps You must enter at least one and up to four IP addresses of SNM...

Страница 16: ...Figure 2 E Device Server Configuration Menu 3116 T31 148 Manual Rev C Page 16 04 22 2015...

Страница 17: ...Menu Execute switch and must also end with the operation of the Menu Execute switch verified by the Save Settings Menu If this sequence is not followed none of the changes will take effect If programm...

Страница 18: ...econds and the system will return to the normal operating mode or scroll to R and push the menu Execute switch and select NO in the SAVE SETTINGS window To change the BAND Operate the Menu Execute swi...

Страница 19: ...nd then push the Menu Execute switch to get to the Gain setting GAIN 20 R Press the Up Down switch to change the gain in 1 or 10 dB steps GAIN 21 R By using the horizontal rocker switch the cursor can...

Страница 20: ...Option Q Menu 8 Interior Temperature Save Settings At the end or when R is selected from any of the above menus ON POWER UP NORMAL DISPLAY PUSHING MENU EXECUTE SEQUENCE FPC 4 00 Load Settings PUSH BUT...

Страница 21: ...pment is not compromised Additional space between units may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that...