2.6 Menu Settings
All program changes must start with the operation of the Menu/Execute switch and must also end with the
operation of the Menu/Execute switch verified by the “Save Settings?” Menu. If this sequence is not followed,
none of the changes will take effect. If programming is initiated and no operator action takes place for
approximately 30 seconds (before the final press of the Menu/Execute switch) the display will revert to its
previous status and you will need to start over.
Figure 2.5 shows the various Front Panel LCD Displays that you will see during the Power Up sequence and
the Settings modes.
ON POWER UP
Power Up
IP Address
Normal Display
Menu 1 Select Settings
CH #1 - CH #4 or Other
Menu 2 Select Mode
CH1-4 Select MGC or
AGC OR Other Settings
Menu 3 Set :
Gain, Output LVL or
Interface
SAVE? When “R” is
selected from any above
menu of at the end.
NORMAL DISPLAY
Scroll
Push Button
<>
<
>
2412-408
5.00
192.168.123.2
AGC L=+2 MGC G=35
MGC G=20 AGC L=+10
WHICH SETTINGS?
#1#2 #3 #4 OTHER R
CHAN 1
MODE= MGC R
CHAN 1
GAIN = +20 R
CHAN 1
MODE= AGC R
CHAN 1
OUTPUT LVL = +10 R
OTHER SETTINGS
REMOTE = ON R
OTHER SETTINGS
INTERFACE = RS232 R
SAVE SETTINGS? YES
SAVE SETTINGS? YES
REPEAT ABOVE SEQUENCE
FOR CHANNELS 1-4
Scroll
Push Button
<>
<
>
FIGURE 2.5 Model 2412-x08 Menu Display and Sequence
2412-408 Manual, Rev. 0
Page 15
09/04/12