background image

1.2   Technical Characteristics

 Channel Characteristics

 Synthesizer Characteristics

 125 kHz minimum

   Frequency Step

 Non-inverting

  Frequency Sense

 0.1 deg/dB maximum for -15 dBm output

   AM/PM Conversion

 1.5dB, 5.845 - 6.725 GHz; Slope 0.05 dB/MHz max.; 36 MHz BW; 
 ±0.5 dB, 36MHz  BW

   Frequency Response

 <-45 dBC for two carriers each at -5 dBm out

   Intermodulation

 +3 dBm  ± 3 dB

   10 MHz In/Out Level

 ±0.01 ppm (1x10E-8) internal ref. (1x10E-9 per day) External ref. input available

   Frequency Accuracy

 0.015 ns/MHz

2

 parabolic; 0.05 ns/MHz linear; 1 ns ripple

  Group Delay, maximum

 <-50 dBC

   Spurious Response

 +10.0 to +30.0 dB, 0.5 dB steps / ±0.25 dB/day max. stability

   Gain Range / Stability

 BNC (female), 75

Ω

, works with 50 ohms

   10 MHz Connectors

 Other

 100-24 ±10% VAC, 47-63 Hz, 45 watts max. 

   Power

 19 inch, 1RU Standard Chassis -  1.75” high X 16.0” deep

   Size

 DB9 (female) - NO or NC contact closure on Alarm

   Alarm/Remote Connector

 -20 dBC Levels; Connectors RF - SMA female; IF - 75

Ω

 BNC female, (front panel)

   RF / IF Monitor Ports

  RF - Type N (female) / IF - BNC (female)

   RF / IF Connectors

         -110

         -95

           -80

          -75

       -70

         1MHz

       100kHz

         10kHz

         1kHz

   100 MHz 

                                  dBC/Hz

   Phase Noise @ Frequency

 Controls, Indicators

 RS232C, 9600 baud 

   Remote

 Direct readout LCD; push-button switches or remote selection

   Frequency / Gain Selection

 Green LED, Red LED, Yellow LED, Yellow LED

   Power, Alarm, Remote, Mute

 TABLE 1.1

2015-58-T Upconverter Specifications*

 -30 to -10 dBm

 Input Level

 20 dB typical; 25 dB maximum, +30 dB gain

 Noise Figure

 70 ±18 MHz

 Frequency

 +10 dBm

 Output 1 dB Compression

 -20  to 0 dBm

 Output Level

 Output Characteristics 

 Input Characteristics

 5.845 to 6.725 GHz

 Frequency

 50

Ω

 / 20 dB Typical, 18 dB min.

 Impedance / Return Loss

 75

Ω

 / 20 dB

 Impedance / Return Loss

   - M

 50

Ω

 Type N (RF), 50

Ω

 BNC (IF)

 

   Connector / Impedance

   Remote M&C Interfaces

 LO1 / LO2 Monitor Ports (Rear)

   - W12

 Available Options

 Ethernet with Web Browser & SNMP

 Ethernet with Web Browser (WB)

   - W18

   - W8

 RS485 Remote Interface

   - Q

 

*+0  to +50 degrees C;  Specifications subject to change without notice.

2015-58T Manual_Rev. D

 

    Page 4

      11/29/12

Содержание 2015-58T

Страница 1: ...nc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment Printed in USA When ordering parts from Cross Technologies Inc be...

Страница 2: ...to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies...

Страница 3: ...cy and gain Parameter selection and frequency and gain settings appear on the LCD display Connectors are BNC female for IF input and 10MHz reference input and output and Type N female for the RF outpu...

Страница 4: ...0 dBC Levels Connectors RF SMA female IF 75 BNC female front panel RF IF Monitor Ports RF Type N female IF BNC female RF IF Connectors 110 95 80 75 70 1MHz 100kHz 10kHz 1kHz 100 MHz dBC Hz Phase Noise...

Страница 5: ...8 9 Female DB 9 PC Com Port Male DB 9 2015 16 17 M C Port M C Cable Diagram Cross Technologies Frequency Converters RX RX TX TX DTR SG DSR RTS CTS SG Connector Rear panel DB 9 female Pinouts RS 485 4...

Страница 6: ...ange 10 to 30 10 dB to 30 dB in 1 dB steps Set Transmit Gain aaC3xxx where xxx 3 characters Range 100 to 300 10 0 dB to 30 0 dB in 0 5 dB steps Enable Tx aaCAx where x 0 to disable Tx signal 1 to enab...

Страница 7: ...equipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect...

Страница 8: ...high by 16 inch deep chassis A switching 12 24 5 VDC power supply provides power for the assembly The 2015 58T can be secured to a rack using the 4 holes on the front panel Figure 2 1 shows how the 2...

Страница 9: ...n 8 Not Used 9 Alarm Relay Normally Closed Interface DB 9 Female Protocol RS 485 RS 422 or RS 232C selectable 9600 baud rate no parity 8 data bits 1 start bit 1 stop bit 2 3 Front Panel Controls and I...

Страница 10: ...The firmware will prevent setting gain and input level outside this range See Section 2 5 Menu Settings 7 Be sure DS6 green DC Power is on and DS2 red Alarm is off Figure 2 3 8 AC Fuse The fuse is a...

Страница 11: ...te Operation option Q Menu 8 Select RS485 Remote Address for Unit option Q Save Menu When R is selected in any of the above menus or when operator reaches the end Alarm indications appear on the LEDs...

Страница 12: ...erator may desire 2 5 3 Control Switches 1 Menu Execute Any change to the programming of the unit must be initiated by pressing the Menu Execute switch and completed by pressing the Menu Execute switc...

Страница 13: ...50 000 R Pressing the Up Down switch down will toggle the display to F 5850 000 R By using the horizontal rocker switch the cursor can be moved left or right F 5850 000 R NOTE CHANGES DO NOT TAKE PLAC...

Страница 14: ...TO SAVE THE CHANGES Press the Up Down switch to change the level in 1 dB steps and then push the Menu Execute switch to get to the Gain setting G 10 0 R Press the Up Down switch to change the gain in...

Страница 15: ...te TX signal Menu 5 Set Unit to Remote Operation Menu 6 Select External 10 MHz Reference Menu 7 Set Remote Mode option Q Menu 8 Set RS 485 Address option Q Save Settings At the end or when R is select...

Страница 16: ...INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2015 58T Manual_Rev D...

Отзывы: