MODEL 2015-58T Upconverter

1.0  General

1.1  Equipment Description

The 2015-58-T Upconverter converts 70 ±18 MHz to 5.845 to 6.725 GHz in 125 kHz steps with low group 
delay and flat frequency response. Synthesized local oscillators (LO) provide low phase noise and ±1.0 ppm 
stability frequency selection. Push button switches select the RF frequency, gain, and other parameters. Front 
panel LEDs provide indication of DC power (green), remote operation (yellow), PLL alarm (red), or the TX 
carrier is muted (yellow). Variable attenuators for the IF input and RF output provide a gain range of 0 to +20 
dB as adjusted by the front panel pushbutton switches. Remote operation allows selection of frequency and 
gain. Parameter selection and frequency and gain settings appear on the LCD display. Connectors are BNC 
female for IF input and 10MHz reference input and output, and Type N female for the RF output (other 
connector configurations available). The 2015-58T is powered by a 100-240 ±10% VAC power supply; and 
housed in a 1.75” X 19” X 16” rack mount chassis.

MENU

EXECUTE

MODEL 2015

C

ROSS 

T

ECHNOLOGIES INC.

F = 5950.000      

G = +10.0     

MUTE

REMOTE

POWER

ALARM

UPCONVERTER

IF MONITOR

RF MONITOR

FRONT

GND

J4

J3

J18

10 MHZ REF

10 MHZ

IF IN

EXT REF

OUTPUT

INPUT

RF OUT

J5

J20

J10

AND

MONITOR

CONTROL

1

5 2

3

4

6

7

8

9

AC

Optional 
Ethernet 

C

t

REAR

FIGURE 1.1     Model 2015-58T Front and Rear Panels

5.85

to

6.425

GHz

OUT

70

MHz

IN

CONTROLLER

F = 5950.0000

G = +10.0    

VAR 

ATT

EXT

10 MHz

INT/EXT

10 MHz

VAR 

ATT

INT

10 MHz

FIGURE 1.2    Model 2015-58T Upconverter Block Diagram

2015-58T Manual_Rev. D

 

    Page 3

      11/29/12

Содержание 2015-58T

Страница 1: ...nc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment Printed in USA When ordering parts from Cross Technologies Inc be...

Страница 2: ...to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies...

Страница 3: ...cy and gain Parameter selection and frequency and gain settings appear on the LCD display Connectors are BNC female for IF input and 10MHz reference input and output and Type N female for the RF outpu...

Страница 4: ...0 dBC Levels Connectors RF SMA female IF 75 BNC female front panel RF IF Monitor Ports RF Type N female IF BNC female RF IF Connectors 110 95 80 75 70 1MHz 100kHz 10kHz 1kHz 100 MHz dBC Hz Phase Noise...

Страница 5: ...8 9 Female DB 9 PC Com Port Male DB 9 2015 16 17 M C Port M C Cable Diagram Cross Technologies Frequency Converters RX RX TX TX DTR SG DSR RTS CTS SG Connector Rear panel DB 9 female Pinouts RS 485 4...

Страница 6: ...ange 10 to 30 10 dB to 30 dB in 1 dB steps Set Transmit Gain aaC3xxx where xxx 3 characters Range 100 to 300 10 0 dB to 30 0 dB in 0 5 dB steps Enable Tx aaCAx where x 0 to disable Tx signal 1 to enab...

Страница 7: ...equipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect...

Страница 8: ...high by 16 inch deep chassis A switching 12 24 5 VDC power supply provides power for the assembly The 2015 58T can be secured to a rack using the 4 holes on the front panel Figure 2 1 shows how the 2...

Страница 9: ...n 8 Not Used 9 Alarm Relay Normally Closed Interface DB 9 Female Protocol RS 485 RS 422 or RS 232C selectable 9600 baud rate no parity 8 data bits 1 start bit 1 stop bit 2 3 Front Panel Controls and I...

Страница 10: ...The firmware will prevent setting gain and input level outside this range See Section 2 5 Menu Settings 7 Be sure DS6 green DC Power is on and DS2 red Alarm is off Figure 2 3 8 AC Fuse The fuse is a...

Страница 11: ...te Operation option Q Menu 8 Select RS485 Remote Address for Unit option Q Save Menu When R is selected in any of the above menus or when operator reaches the end Alarm indications appear on the LEDs...

Страница 12: ...erator may desire 2 5 3 Control Switches 1 Menu Execute Any change to the programming of the unit must be initiated by pressing the Menu Execute switch and completed by pressing the Menu Execute switc...

Страница 13: ...50 000 R Pressing the Up Down switch down will toggle the display to F 5850 000 R By using the horizontal rocker switch the cursor can be moved left or right F 5850 000 R NOTE CHANGES DO NOT TAKE PLAC...

Страница 14: ...TO SAVE THE CHANGES Press the Up Down switch to change the level in 1 dB steps and then push the Menu Execute switch to get to the Gain setting G 10 0 R Press the Up Down switch to change the gain in...

Страница 15: ...te TX signal Menu 5 Set Unit to Remote Operation Menu 6 Select External 10 MHz Reference Menu 7 Set Remote Mode option Q Menu 8 Set RS 485 Address option Q Save Settings At the end or when R is select...

Страница 16: ...INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2015 58T Manual_Rev D...

Отзывы: