background image

1.4  Environmental Use Information

ARack-Mounting - To mount this equipment in a rack, please refer to the installation instructions 

located in the user manual furnished by the manufacturer of your equipment rack.

B. Mechanical Loading - Mounting of equipment in a rack should be such that a hazardous condition 

does not exist due to uneven weight distribution.

CElevated Operating Ambient Temperature - If installed in a closed or multi-unit rack assembly, 

the operating ambient temperature of the rack may be greater than room ambient temperature.  
Therefore, consideration should be given to Tmra.

D. Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of air flow 

required for safe operation of the equipment is not compromised.  Additional space between unit 
may be required.

E. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply 

circuit and the effect that overloading of circuits could have on over current protection and supply wiring.  
Appropriate consideration of equipment name plate rating should be used, when addressing this concern.

F. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained.  

Particular attention should be given to supply connections other than direct connection to the 
Branch (use of power strips).

G. Top Cover - There are no serviceable parts inside the product so, the Top Cover should not be removed.  

If the Top Cover is removed the ground strap and associated screw MUST BE REINSTALLED 
prior to Top Cover screw replacement.  FAILURE TO DO this may cause INGRESS and/or EGRESS 
emission problems.

2015-58T Manual_Rev. D

 

    Page 7

      11/29/12

Содержание 2015-58T

Страница 1: ...nc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment Printed in USA When ordering parts from Cross Technologies Inc be...

Страница 2: ...to customer Cross Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies...

Страница 3: ...cy and gain Parameter selection and frequency and gain settings appear on the LCD display Connectors are BNC female for IF input and 10MHz reference input and output and Type N female for the RF outpu...

Страница 4: ...0 dBC Levels Connectors RF SMA female IF 75 BNC female front panel RF IF Monitor Ports RF Type N female IF BNC female RF IF Connectors 110 95 80 75 70 1MHz 100kHz 10kHz 1kHz 100 MHz dBC Hz Phase Noise...

Страница 5: ...8 9 Female DB 9 PC Com Port Male DB 9 2015 16 17 M C Port M C Cable Diagram Cross Technologies Frequency Converters RX RX TX TX DTR SG DSR RTS CTS SG Connector Rear panel DB 9 female Pinouts RS 485 4...

Страница 6: ...ange 10 to 30 10 dB to 30 dB in 1 dB steps Set Transmit Gain aaC3xxx where xxx 3 characters Range 100 to 300 10 0 dB to 30 0 dB in 0 5 dB steps Enable Tx aaCAx where x 0 to disable Tx signal 1 to enab...

Страница 7: ...equipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect...

Страница 8: ...high by 16 inch deep chassis A switching 12 24 5 VDC power supply provides power for the assembly The 2015 58T can be secured to a rack using the 4 holes on the front panel Figure 2 1 shows how the 2...

Страница 9: ...n 8 Not Used 9 Alarm Relay Normally Closed Interface DB 9 Female Protocol RS 485 RS 422 or RS 232C selectable 9600 baud rate no parity 8 data bits 1 start bit 1 stop bit 2 3 Front Panel Controls and I...

Страница 10: ...The firmware will prevent setting gain and input level outside this range See Section 2 5 Menu Settings 7 Be sure DS6 green DC Power is on and DS2 red Alarm is off Figure 2 3 8 AC Fuse The fuse is a...

Страница 11: ...te Operation option Q Menu 8 Select RS485 Remote Address for Unit option Q Save Menu When R is selected in any of the above menus or when operator reaches the end Alarm indications appear on the LEDs...

Страница 12: ...erator may desire 2 5 3 Control Switches 1 Menu Execute Any change to the programming of the unit must be initiated by pressing the Menu Execute switch and completed by pressing the Menu Execute switc...

Страница 13: ...50 000 R Pressing the Up Down switch down will toggle the display to F 5850 000 R By using the horizontal rocker switch the cursor can be moved left or right F 5850 000 R NOTE CHANGES DO NOT TAKE PLAC...

Страница 14: ...TO SAVE THE CHANGES Press the Up Down switch to change the level in 1 dB steps and then push the Menu Execute switch to get to the Gain setting G 10 0 R Press the Up Down switch to change the gain in...

Страница 15: ...te TX signal Menu 5 Set Unit to Remote Operation Menu 6 Select External 10 MHz Reference Menu 7 Set Remote Mode option Q Menu 8 Set RS 485 Address option Q Save Settings At the end or when R is select...

Страница 16: ...INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com Printed in USA 2015 58T Manual_Rev D...

Отзывы: