2.2  Rear Panel Input/Output Signals - Figure 2.2 shows the input and output connectors on the rear panel.

    

REF IN

RF

RF+DC

J1

J3

J2

F1

FUSE

DS1

DC
ON

RF

CAUTION!  RISK OF

ELECTRIC SHOCK

DO NOT OPEN!!!

100-240 

±

10%

VAC

 

47-63 HZ
FUSE 2A

J1 - RF + DC
The looped signal from J2 containing 
the in18VDC/+24VDC and/or 
10MHz referernce

J3 - REF IN
Connect the external 10 MHz 
reference signal to be inserted 
at RF+DC here.

F1 - FUSE
When the provided fuse is inserted, 
+18VDC/+24VDC,  2.5 amps max 
will be present at RF+DC

DS1 - DC ON RF
Lights yellow when 
+18VDC/+24VDC is present 
at RF+DC.

J2 - RF
The RF signal upon which you wish to 
insert the +18VDC/+24VDC and/or the 
10MHz reference

FIGURE 2.2  Rear Panel I/Os 

TABLE  2.1  Coonnector 

C

onnector  Options

Option

RF

STD

Type F, 75

-B

BNC, 75

-D

BNC, 50

2.3  Front Panel Indicators - The following are the front panel indicators.

DS2 - POWER LED
Lights green when DC 
power is present

POWER

C

ROSS 

T

ECHNOLOGIES, INC.

2000 POWER SUPPLY

FIGURE 2.3  Front Panel Indicators

2000-318/324 Manual_Rev 0

                             Page 6

                                 11/23/09

Содержание 2000-318

Страница 1: ...d or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment model nu...

Страница 2: ...nc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be liable for any...

Страница 3: ...10 MHz reference signal on the RF line The input AC connector is IEC 320 C13 The 2000 318 324 can be mounted on an optional 1 3 4 X 19 rack mount panel option R POWER CROSS TECHNOLOGIES INC 2000 POWER...

Страница 4: ...24 VDC 2 5 amps Model 2000 324 Load Regulation max 5 Power Supply type Switcher Switching Frequency 50 kHz typical Indicators DC Power front Green LED DC Power Insertion rear Yellow LED Other AC Inpu...

Страница 5: ...nel that can be mounted to a rack using the 4 holes at the ends EXTRUSION FRONT SCREWS 4EA FRONT PANEL RACK MOUNT PANEL FOR R MODELS ONLY REAR SCREWS 4EA PCB ASSEMBLY REAR PANEL POWER SUPPLY CABLE 200...

Страница 6: ...1 FUSE When the provided fuse is inserted 18VDC 24VDC 2 5 amps max will be present at RF DC DS1 DC ON RF Lights yellow when 18VDC 24VDC is present at RF DC J2 RF The RF signal upon which you wish to i...

Страница 7: ...the back panel Figure 2 2 6 Be sure DS2 green DC Power is on Figure 2 3 7 If fuse F1 is inserted check that SSPB Power LED DS1 is on Figure 2 2 8 AC FUSE The AC fuse is a 5 mm X 20 mm 2 amp slow blow...

Страница 8: ...uipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect tha...

Страница 9: ...LOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 2000 318 324 Manual_Rev 0 Page...

Отзывы: