2.5 Environmental Use Information

ARack-Mounting - To mount this equipment in a rack, please refer to the installation instructions 

located in the user manual furnished by the manufacturer of your eqipment rack.

B. Mechanical loading - Mounting of equipment in a rack should be such that a hazardous condition 

does not exist due to uneven weight distribution.

CElevated operating ambient temperature - If installed in a closed or multi-unit rack assembly, 

the operating ambient temperature of the rack may be greater than room ambient temperature.  
Therefore, consideration should be given to Tmra.

D. Reduced air flow - Installation of the equipment in a rack should be such that the amount of air flow 

required for safe operation of the equipment is not compromised.  Additional space between unit 
may be required.

E. Circuit Overloading - Consideration should be given to the connection of the equipment to the supply 

circuit and the effect that overloading of circuits could have on over current protection and supply wiring.  
Appropriate consideration of equipment name plate rating should be used, when addressing this concern.

F. Reliable Earthing - Reliable earthing of rack-mounted equipment should be maintained.  Particular 

attention should be given to supply connections other than direct connection to the Branch 
(use of power strips).

G. Top Cover - There are no servicable parts inside the product so, the Top Cover should not be removed.  

If the Top Cover is removed the ground strap and associated screw MUST BE RE-INSTALLED 
prior to Top Cover screw replacement.  FAILURE TO DO this may cause INGRESS and/or EGRESS 
emission problems.

2000-318/324 Manual_Rev 0

                             Page 8

                                 11/23/09

Содержание 2000-318

Страница 1: ...d or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment model nu...

Страница 2: ...nc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be liable for any...

Страница 3: ...10 MHz reference signal on the RF line The input AC connector is IEC 320 C13 The 2000 318 324 can be mounted on an optional 1 3 4 X 19 rack mount panel option R POWER CROSS TECHNOLOGIES INC 2000 POWER...

Страница 4: ...24 VDC 2 5 amps Model 2000 324 Load Regulation max 5 Power Supply type Switcher Switching Frequency 50 kHz typical Indicators DC Power front Green LED DC Power Insertion rear Yellow LED Other AC Inpu...

Страница 5: ...nel that can be mounted to a rack using the 4 holes at the ends EXTRUSION FRONT SCREWS 4EA FRONT PANEL RACK MOUNT PANEL FOR R MODELS ONLY REAR SCREWS 4EA PCB ASSEMBLY REAR PANEL POWER SUPPLY CABLE 200...

Страница 6: ...1 FUSE When the provided fuse is inserted 18VDC 24VDC 2 5 amps max will be present at RF DC DS1 DC ON RF Lights yellow when 18VDC 24VDC is present at RF DC J2 RF The RF signal upon which you wish to i...

Страница 7: ...the back panel Figure 2 2 6 Be sure DS2 green DC Power is on Figure 2 3 7 If fuse F1 is inserted check that SSPB Power LED DS1 is on Figure 2 2 8 AC FUSE The AC fuse is a 5 mm X 20 mm 2 amp slow blow...

Страница 8: ...uipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect tha...

Страница 9: ...LOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 2000 318 324 Manual_Rev 0 Page...

Отзывы: