background image

MODEL 2000-318/324 SSPB Power Supply

1.0  General

1.1  Equipment Description

The 2000-318/324 SSPB Power Supply is a switching power supply which provides reg18 VDC (-318) 
OR +24 VDC (-324) at 2.5 amps through RF connectors for insertion on an RF line.  Also provided is a BNC 
connector for insertion of a 10 MHz reference signal on the RF line.  The input AC connector is IEC 320 C13.  
The 2000-318/324 can be mounted on an optional 1 3/4” X 19” rack mount panel (option -R).
 

POWER

C

ROSS 

T

ECHNOLOGIES, INC.

2000 POWER SUPPLY

FRONT PANEL

REF IN

RF

RF+DC

J1

J3

J2

F1

FUSE 

DS1

DC
ON

RF

CAUTION!  RISK OF

ELECTRIC SHOCK

DO NOT OPEN!!!

100-240 

±

10%

VAC

47-63 HZ
FUSE 2A

REAR PANEL

FIGURE 1.1  Front and Rear Panels

RF

LNB

+24 VDC

EXT 10MHz

fuse

RF+DC

SURGE

SUPPRESOR

FIGURE 1.2   Block Diagram

2000-318/324 Manual_Rev 0

                             Page 3

                                 11/23/09

Содержание 2000-318

Страница 1: ...d or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to include the equipment model nu...

Страница 2: ...nc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be liable for any...

Страница 3: ...10 MHz reference signal on the RF line The input AC connector is IEC 320 C13 The 2000 318 324 can be mounted on an optional 1 3 4 X 19 rack mount panel option R POWER CROSS TECHNOLOGIES INC 2000 POWER...

Страница 4: ...24 VDC 2 5 amps Model 2000 324 Load Regulation max 5 Power Supply type Switcher Switching Frequency 50 kHz typical Indicators DC Power front Green LED DC Power Insertion rear Yellow LED Other AC Inpu...

Страница 5: ...nel that can be mounted to a rack using the 4 holes at the ends EXTRUSION FRONT SCREWS 4EA FRONT PANEL RACK MOUNT PANEL FOR R MODELS ONLY REAR SCREWS 4EA PCB ASSEMBLY REAR PANEL POWER SUPPLY CABLE 200...

Страница 6: ...1 FUSE When the provided fuse is inserted 18VDC 24VDC 2 5 amps max will be present at RF DC DS1 DC ON RF Lights yellow when 18VDC 24VDC is present at RF DC J2 RF The RF signal upon which you wish to i...

Страница 7: ...the back panel Figure 2 2 6 Be sure DS2 green DC Power is on Figure 2 3 7 If fuse F1 is inserted check that SSPB Power LED DS1 is on Figure 2 2 8 AC FUSE The AC fuse is a 5 mm X 20 mm 2 amp slow blow...

Страница 8: ...uipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect tha...

Страница 9: ...LOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 2000 318 324 Manual_Rev 0 Page...

Отзывы: