background image

INSTRUCTION MANUAL

MODEL 1584-29 RF Splitter 

TABLE OF CONTENTS

PAGE

Warranty

2

1.0  General

3

1.1  Equipment Description

3

1.2  Technical Characteristics

4

1.3  Environmental Use Information

5

2.0  Installation

6

2.1  Mechanical

6

2.2  Rear Panel Input/Output Connectors

 7 

2.3  Front Panel Monitors and Indicators

7

2.4  Operation

8

WARRANTY - The following warranty applies to all Cross Technologies, Inc. products.

All Cross Technologies, Inc. products are warranted against defective  materials and 
workmanship for a period of one year after shipment to customer.  Cross  Technologies, 
Inc.’s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc.’s 
option, replacing parts, subassemblies, or entire assemblies.  Cross Technologies, Inc. shall 
not be liable for any special, indirect, or consequential damages.  This warranty does not 
cover parts or equipment which have been subject to misuse, negligence, or accident by the 
customer during use.  All shipping costs for warranty repairs will be prepaid by the 
customer.  There are not other warranties, express or implied, except as stated herein.

C

ROSS 

T

ECHNOLOGIES, INC.

6170 Shiloh Road

Alpharetta, Georgia 30005

(770) 886-8005

FAX (770) 886-7964

Toll Free 888-900-5588

WEB www.crosstechnologies.com 

E-MAIL [email protected]

1584-29 Manual, Rev C 

 

 Page 2

    

              3/7/19

Содержание 1584-29

Страница 1: ...ies Inc but may be reproduced or duplicated without the prior permission of Cross Technologies Inc for purposes of operating the equipment When ordering parts from Cross Technologies Inc be sure to in...

Страница 2: ...s Technologies Inc s obligation under this warranty is limited to repairing or at Cross Technologies Inc s option replacing parts subassemblies or entire assemblies Cross Technologies Inc shall not be...

Страница 3: ...ltage transients All splitter outputs are AC coupled so no DC appears on their center conductors On the front panel green LEDs indicate presence of 22 VDC at each LNB power supply output and DC voltag...

Страница 4: ...Isolation 18 dB min 20 dB typ Coupler to Coupler Isol 35 dB min 40 dB typ Indicators Power Green LED indicates DC voltage prior to diode OR and to amplifiers Other LNB DC voltage 22 2 VDC Output Ampl...

Страница 5: ...e equipment is not compromised Additional space between unit may be required E Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect...

Страница 6: ...1584 29 can be secured to a rack using the 4 holes on the front panel Figure 2 1 shows how the 1584 29 is assembled J27 and J25 connect DC Power to the fuses as shown and J30 and J29 connect the DC vo...

Страница 7: ...t Blo 1 4 Fuse FUSE FOR LNB1 1 amp Fast Blo 1 4 Fuse IN J17 OUT J16 OUT J15 OUT J14 OUT J13 OUT J12 OUT J11 OUT J10 OUT J9 IN J19 OUT J8 OUT J7 OUT J6 OUT J5 OUT J4 OUT J3 OUT J1 OUT J2 FIGURE 2 1 158...

Страница 8: ...nstalled in the rear panel fuse holders to insure proper signals and voltages NOTE FOR OPTIMUM PERFORMANCE THE MONITOR PORT AND SPLITTER PORTS SHOULD BE TERMINATED WITH 75 OHM TYPE F TERMINATIONS WHEN...

Страница 9: ...CHNOLOGIES INC 6170 Shiloh Road Alpharetta Georgia 30005 770 886 8005 FAX 770 886 7964 Toll Free 888 900 5588 WEB www crosstechnologies com E MAIL info crosstechnologies com 1584 29 Manual Rev C Page...