manualshive.com logo in svg
background image

CRL ESK1/ESP1 - ELECTRIC STRIKE KEEPER FOR SINGLE DOORS

07

crlaurence.com   |   usalum.com

NOT TO SCALE

FIG. 4

DOOR RAIL MOUNTING

Folger Adam 310-1 

Electric Strike with 

3/4" (19) Straight 

Keeper

Adjustable 

Bolt/Stop

Electric Strike 

Parallel to Door

2 F.O.G.

Header

ELECTRIC STRIKE APPLICATIONS 

DOOR RAIL APPLICATION AND DIRECT TO GLASS APPLICATION  

Adjustable 

Bolt/Stop

2 F.O.G.

DIRECT TO GLASS MOUNTING

FIG. 5

Header

FIG. 6

NOTE: Face of the Strike Keeper 

 

MUST

 be set at 87 degrees as 

 

illustrated in Figure 6. To adjust 

 

the Strike refer to page 10. 

Electric Wires

Header

Face of the Strike Keeper  

factory preset at 87 degrees

87º

Electric Strike  

Mounting Bolts

Folger Adam 310-1 

Electric Strike with 

3/4" (19) Straight Keeper

Door Stop 

Mounting Bolts

Door Stop 

Cover (included)

Cover Retaining 

Screw

D

Folger Adam 310-1 

Electric Strike with 

3/4" (19) Straight Keeper

E

ESK01 

Rail Stop 

Screw

ESK02 

Glass Stop 

Screw

3/16" (5) 

Gap

3/16" (5) 

Gap

Содержание ESK1

Страница 1: ...TALLATION INSTRUCTIONS CRL ESK1 ESP1 ELECTRIC STRIKE KEEPER FOR SINGLE DOORS ALUMINUM Phone 800 421 6144 Fax 800 587 7501 crlaurence com usalum com crl arch com NOTE Sensor feature available on ESP St...

Страница 2: ...ON 08 11 VOLTAGE AND WIRING 08 ELECTRIC STRIKE ATTACHMENT 09 ELECTRIC STRIKE ADJUSTMENT 10 RE ATTACH STRIKE COVER AND MAKE FINAL ADJUSTMENTS 11 The rapidly changing technology within the architectural...

Страница 3: ...i A156 3 Exit Devices iii A156 18 Materials and Finishes b Americans with Disabilities Act A D A c American Society for Testing and Materials ASTM d National Fire Protection Association NFPA 101 e Und...

Страница 4: ...1 SHCS Stop Screw for Glass Mount Doors Bumper Sold Separately 2 BMPRBR Rubber Bumper for Strike D E FASTENERS AND PARTS LIST CALL OUT QTY FASTENER FASTENER DESCRIPTION PART USED WITH PART NUMBER 2 5...

Страница 5: ...TACHED TEMPLATE INTERIOR FIG 1 Drill and Tap 5 16 18 x 3 4 UNC 2 Places Centerline of Pivot 4 1 8 104 8 to Leading Edge Swing 3 This Side 4 1 8 104 8 to Leading Edge Swing 4 This Side 1 25 4 on 1 2 12...

Страница 6: ...m NOT TO SCALE HEADER PREPARATION CONTINUED Interior Edge of Header Use Template from Box Drill and Tap for a 2 5 16 18 x 3 4 SHCS REINSTALL THE PREPARED HEADER AND CONTINUE WITH THE ELECTRIC STRIKE I...

Страница 7: ...p 2 F O G DIRECT TO GLASS MOUNTING FIG 5 Header FIG 6 NOTE Face of the Strike Keeper MUST be set at 87 degrees as illustrated in Figure 6 To adjust the Strike refer to page 10 Electric Wires Header Fa...

Страница 8: ...Before installing the strike make the necessary wire connections Refer to the table below in Fig 7 for ESK ESP strikes for latch deadbolt and monitor on ESP strikes only 2 When you are installing the...

Страница 9: ...SHCS A ELECTRIC STRIKE ATTACHMENT CONTINUED 1 Fasten the Electric Strike to the header using 2 5 16 18 x 3 4 SHCS Fig 8 2 Check the horizontal alignment Make sure that the centerline of the latch bol...

Страница 10: ...12 F Push and hold the Strike Keeper in against the Jig and re tighten the 2 1 4 20 x 1 2 SHCS Fig 13 G Remove the ESP040 Electric Offset Jig Fig 14 H Install the Electric Strike Assembly using the 2...

Страница 11: ...against the rubber stop pads the retractable bolt should automatically move upward to engage the Strike 3 If it does NOT engage the door stops should be adjusted inward Do not overtighten This can cau...

Отзывы: