9
The electrical installation must follow the data from the table below:
Your
Cristófoli Distiller has the following safety devices:
SAFETY FEATURES AND DEVICES
THERMAL FUSE
(equipment internal device)
-
There is a thermal fuse attached to
the heating element. Its function is to limit equipment overheating during
operation. If the thermostat fails, the thermal fuse will be activated to cut the
current safely;
THERMOSTAT
-
(equipment internal device)
-
Its function is to limit equipment
excessive heating during operation;
WATER LEVEL DEVICE
-
It is located in the back part of the main unit (Fig.7, item 12,
page 12). The purpose of this device is to turn the distiller off automatically in the
following cases:
- the water in the tap water container is finished or its water exit is obstructed;
- the tap water container is removed;
After filling the tap water container, the distiller must be reset. Press “OFF” on the
On/Off Switch to and then back to “ON-Reset”;
When the distiller is tilted or lifted it will shut off automatically.
Outlet and plug with grounding pin
(three pins or 2P + T) 10A.
MODEL
AMPERAGE
VOLTAGE
Cristófoli Distiller
127 V~ - - - - - - - - - - - 4,3 A
220 V~ - - - - - - - - - - - 2,2 A
C R I S T Ó F O L I
D I S T I L L E R
I N S T R U C T I O N M A N U A L
Fig.1