INSTALLER TEST MODE
Installer Test Mode is helpful for a number of reasons:
•
Quick, Easy testing of the system without having to continually arm/disarm
•
Test the systems reset, re-arm, and bypass logic
•
Review up last 4 triggers codes to diagnose false alarm problems
TO ENGAGE TEST MODE:
1. Turn ignition on/of 5 times. Ignition should end up in the off position/
2. The dash LED should come on solid for 4-8 Seconds, then begin flashing the diagnostic
TO DISENGAGE TEST MODE:
1. Turn Ignition on/off once. Test mode will now be off, and all normal functions will resume.
TESTING PROCEDURES Intrusion Zones:
1. Arm system with transmitter
2. Wait for LED to start flashing rapidly
3. Open and close door or hood/trunk.
4. System should sound siren for 4 seconds, then shut OFF.
5. Check Dash LED to see if it shows one trigger (One Flash every 2 Sec.)
6. Open door or hood/trunk and leave open. Siren should sound for 8 seconds, then shut OFF. Dash LED will flash 3
times indicating bypassed door zone after (2) cycles. Alarm is still armed with door zone bypassed.
7. Disarm system with transmitter. # chirps should sound indicating prior intrusion
TESTING PROCEDURES Sensors:
1. Arm system with transmitter
2. Wait 10-30 seconds for sensors to settle and become active. Dash LED should be flashing rapidly.
A.
Dual-Stage Shock Sensor: Tap or Slap on a window or bumper with light to medium force. This should trigger the
PRE-WARNING with 6 chirps. Tap harder until the system produces a full trigger.
DO NOT use enough force to
cause damage to vehicle. Use an open palm when slapping window.
B. Glass Break Sensor: Follow Steps “1, 2 ,and A” above, but use a coin to tap on window.
C. Radar/Proximity Sensor: Follow Steps “1 and 2 above, but leave a window and/or sunroof open. Reaching inside
vehicle through the open window or sunroof should produce a full alarm trigger. Dual Stage Sensors Should PRE-
WARN if you move or walk deliberately close to the vehicle. NOTE: Some systems will not trigger instantly if a pre-
warn has already started. These systems will have to produce a pre-warn first, then they will go into a full trigger.
3. ADJUST ALL SENSORS AS NEEDED. DISENGAGE TEST MODE WHEN FINISHED.