background image

 

15 

OPERATING INSTRUCTIONS 

 

TRUNK/HATCH POP (REMOTE AUX. OUTPUT 1, OPTIONAL) 

To pop the trunk (if optional feature is installed), press Button #3 (Trunk Symbol) on the transmitter for at least 
1½ seconds.  

If the system is armed, pressing Button #3 may or may not trip the alarm system when opening 

the trunk depending on programming option (10).  See page 10. 

 

REMOTE PANIC PROTECTION 

To sound the alarm upon command (panic), press and hold the Button #4 (Panic) for at least 2 seconds until 
the siren sounds.  Press Button #2 (Unlock) to reset panic mode. 

 

PRE-WARNING SHOCK PROTECTION & SENSOR ADJUSTMENT 

If a low-level shock to the vehicle is detected, pre-warning protection will activate sounding 5 quick siren chirps 
and  1  light  flash.    If  a  hard  impact  is  detected  the  shock  sensor  should  trip  the  alarm  system.    Once  it  is 
mounted,  adjust  the  sensor  as  needed  by  turning  the  adjustment  screws  clockwise  to  increase  or  counter-
clockwise  to  decrease  the  sensitivity.    The  sensor  is  also  equipped  with  2  small  indicator  lights  to  ease  the 
adjustment process.  Green light = Pre-warning disturbance (6 siren chirps).  Red light = A full alarm trip. 

 

SELECTIVE SILENT ARM/DISARM THROUGH REMOTE CONTROL 

This system can be armed and disarmed without siren chirps on an “as needed” basis.  Press the Bank #2 on 
the side of the remote and within 3 seconds use the lock/unlock buttons to arm/disarm without siren chirps. 

 

PROGRAMMABLE SILENT ARM/DISARM MODE (CHIRP DEFEAT) 

The system can be silently armed and disarmed as normal with Lock/Unlock Buttons, but no siren chirp.  See 
alarm programming option (#8) to enable or disable this feature.  See page 10. 

 

EMERGENCY OVERRIDE / DISARM 

If  you  have  lost  the  transmitter  or  it  stops  working  for  any  reason  and  the  Alarm  is  armed,  you  will  have  to 
open the door with the key, which will activate the alarm.  Turn the ignition on and press the override/program 
button  for  about  3  seconds  (until  siren  stops).    The  Alarm  will  disarm.    If  you  continue  to  hold  the  button  for 
additional 3 seconds, the system will enter the Valet mode. 

 

EMERGENCY DISARM WITH CUSTOM OVERRIDE 

If  you  have  programmed  your  system  for  Custom  Override,  follow  the  same  steps  above  (Emergency 
Override) while pressing the valet button 2-15 times as you have programmed.  You must continue to hold the 
button down on the last press for 5 seconds.  The Alarm will disarm and enter the Valet mode, which allows 
you to use the vehicle until you can repair/replace the remote transmitter or have the alarm system checked.   

 

Содержание CS-2002DPII

Страница 1: ...lt with your installer beforehand i e Door Locks Starter disable Hood Trunk trigger and Auxiliary Remote Outputs etc This installation book is designed for the installer or individual with an existing understanding of automotive electrical systems along with the ability to test and connect wires for proper operation To ease installation we suggest that you READ THIS MANUAL before beginning your in...

Страница 2: ...all vehicle manufacturer cautions and warnings regarding electrical service AIR BAGS ABS BRAKES ENGINE COMPUTERS BATTERY etc WE RECOMMEND the use of a VOLT OHM METER to test and verify wiring circuits Test lights or illuminated probes can cause damage to on board computer or engine management systems DO NOT exceed maximum output ratings WE RECOMMEND that the MAIN SYSTEM FUSE be REMOVED before jump...

Страница 3: ...rd Run the red siren wire through the firewall using a rubber grommet Ground the black to the body metal near the siren or you can use one of the siren s mounting screws for a ground Shock Sensor Mount the included shock sensor with wire ties to an under dash wire harness or fasten with screws to firewall or side paneling Use the adjustment screw to set the sensitivity of the sensor One screw adju...

Страница 4: ...witches are available install new pin switches if desired Note DO NOT mount new pin switches in water pathways BLACK WHITE WIRE NEGATIVE DOME LIGHT ILLUMINATION OUTPUT Optional requires a relay This wire provides a negative ground when the system is disarmed to activate a vehicles dome light circuit We recommend the use of a relay for this connection Connect Black White to terminal 85 of relay Con...

Страница 5: ...of the parking lights at the front of the vehicle If your vehicle requires a Negative Ground signal to activate the parking lights then you have to move the jumper located on the circuit board inside the unit For European vehicles with separate right and left circuits use a dual relay or 2 diodes to separate the output signal The DEFAULT output is Positive Carefully snap open the control module an...

Страница 6: ...TE ALARM STATUS LED INDICATOR Mount the LED Valet Pod in a visible location of the dash or console 4 PIN SENSOR PLUG HARNESS BLUE White Wire Negative Trigger Blue Wire Negative Warn away Black Wire Sensor Ground Red Wire Sensor Power SHOCK SENSOR The sensor supplied with this system does not require any additional wiring Simply mount the sensor in a suitable location plug it in and adjust the sens...

Страница 7: ... FUSED RED 12V RED BLUE BLUE 86 85 86 85 87 87 30 87A 30 87A FACTORY FACTORY L L POWER POWER LOCKING LOCKING UL UL RELAYS RELAYS REVERSE POLARITY DOOR LOCK WIRING GREEN GREEN FUSED FUSED RED RED 12V 12V BLUE BLUE 86 85 86 85 86 85 86 85 87 87 87 87 30 87A 30 87A 30 87A 30 87A L CUT UL CUT MASTER SWITCH ...

Страница 8: ...REEN RED BLUE DRIVER S DOOR MOTOR 86 85 L L 87 UL UL 87A 30 FACTORY LOCK RELAYS 12V FUSED UNLOCK WIRE CUT WIRING FOR REVERSE POLARITY DOOR LOCKS BLUE WHITE GREEN FUSED RED 12V BLUE MASTER 86 85 86 85 SWITCH 86 85 87 87 87 30 87A 30 87A 30 87A L CUT UL CUT CUT UNLOCK WIRE LOCK WIRE ...

Страница 9: ...ton 1 Lock on the remote you wish to program 4 You should get 2 chirps and light flashes indicating the unit is waiting for the second code to learn Press button 1 of a second transmitter the unit will chirp and flash 3 times Press the lock button on a 3rd or 4th transmitter for up to 4 total Note The unit will not flash the lights when learning the 4th code Turn key off to exit programming mode I...

Страница 10: ...ions check operation PROGRAMMING OPTIONS CHART Default Setting Option Option Description BUTTON 1 LOCK BUTTON 2 UNLOCK BUTTON 3 TRUNK 1 Factory Horn Chirps Pulses Pulse with trip only Arm Disarm Chirps Pulse with trip Arm Disarm Warn Chirp Pulse with trip 2 Passive Arming Passive Chirp Countdown ON OFF Passive Arm with Chirp Countdown 3 Passive Lock Custom Override ON OFF Custom Override 4 Ignitio...

Страница 11: ...nd OFF for passive arming to reactivate 3 PASSIVE LOCKS CUSTOM OVERRRIDE ALSO SEE CUSTOM OVERRIDE SECTION PAGE 13 This option controls whether the doors will lock when Passive Arming occurs Note May increase the risk of locking keys in the vehicle When selected ON the alarm will passively lock the doors when passive arming 4 IGNITION CONTROLLED LOCKS This option controls whether the locks are cont...

Страница 12: ... lock unlock pulse The 3 sec setting may be required for 1980 90 s European Vehicles that require a long pulse to do Vacuum door lock systems 13 ACTIVE PASSIVE or FULL TIME CARJACK PROTECTION This feature controls the type of Carjack protection the alarm will provide There are 3 selections Button 1 Lock Active protection Button 2 Unlock Active Passive protection Button 3 Trunk Full Time protection...

Страница 13: ...am button three times to go to option 3 Passive Locks Custom Override 3 Press the Button 3 TRUNK on the remote transmitter 4 Press and release the program again the number of times you desire in order to perform emergency disarm on this alarm system Press the program button 2 15 times only You need to wait for the siren to chirp the same number of times you pressed the program button to confirm To...

Страница 14: ...The red LED in the vehicle will start flashing after 5 seconds After a short delay to allow vehicle and electronics to stabilize the system will be completely armed ALARM TRIGGERING If there is an intrusion into the vehicle or hard impact to the body will sound the alarm and flash the lights for 45 seconds After 45 seconds the system will automatically shut off and re arm to continue to protect th...

Страница 15: ... DISARM THROUGH REMOTE CONTROL This system can be armed and disarmed without siren chirps on an as needed basis Press the Bank 2 on the side of the remote and within 3 seconds use the lock unlock buttons to arm disarm without siren chirps PROGRAMMABLE SILENT ARM DISARM MODE CHIRP DEFEAT The system can be silently armed and disarmed as normal with Lock Unlock Buttons but no siren chirp See alarm pr...

Страница 16: ...rms 30 seconds later DOMESTIC SOFTWARE ONE TIME PASSIVE ARMING Passive Arming will work only one time after the ignition is turned off When you disarm the alarm and re enter vehicle the alarm system will not Passive Re Arm EXPORT SOFTWARE FULL TIME PASSIVE ARMING The alarm system will always Passive Re Arm after disarm The ignition must be turned on to stop Passive Arming PRIOR INTRUSION ALERT If ...

Страница 17: ...er will be activated CARJACK PROTECTION FEATURES ACTIVE CARJACK This feature provides Active Carjack protection and must be enabled before use through Alarm programming option 14 See page 10 When the Ignition is on vehicle is running press button 4 Panic Parking lights will flash TWICE to confirm the Carjack countdown sequence LED begins to flash slowly 90 Seconds later the unit will begin a Carja...

Страница 18: ... the IGNITION is turned on or a door is opened and closed when the ignition is on To reset Ignition must be ON doors must be closed then press override program button 3 times NOTE When FULL TIME CARJACK is in effect it must be reset every time the key is turned on Door is opened before entering VALET mode and before Programming options or transmitters It is always in effect each time the Ignition ...

Страница 19: ...ER CHASSIS GROUND SWITCHED IGN ON SIREN PARKING NEG ARMED OUTPUT OPT RELAY 85 86 87 30 87a 85 86 87 30 87a 12V 10A MAX or 3A MAX LIGHTS FUSE 15A CUT START WIRE STARTER REMOTE OUTPUT 2 85 86 87 30 87a SHOCK SENSOR NEG PIN SWITCH DOME LIGHT OUTPUT 12V POWER PASSENGER UNLOCK OUTPUT ACTIVATES ON SECOND PRESS OF UNLOCK BUTTON OR DOME LIGHT BROWN WHITE HORN HONK OUTPUT OPT RELAY CONNECT TO OPTIONAL DEVI...

Страница 20: ...the side of the unit Please refer to Databus module manual for detail instructions Option 16 controls the Data Port Protocol for 1 Way OFA modules or 2 Way SL modules The default is set for 2 Way Protocol This option has no effect on conventional wiring of Bypass modules iDATA LINK CABLE Data Port Module Not Included OFA Bypass Module CS 2002DPII 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 BCM OBD conn...

Отзывы: